Connect the electric lock to the output as follows:2N Helios IP Security Relay
®
To the active 12 V / 700 mA DC output, or
To the passive output in series with an external power supply.
The device also supports a Departure button connected between the ‘PB’ and ‘-
HeliosIP’ terminals. Press the Departure button to activate the output for 5 seconds.
Status signalling:
Green LED Red LED Status
flashing off Operational mode
on off Activated output
flashing flashing Programming mode – waiting for initialisation
on flashing Error – wrong code received
Configuration:
Connect the to the properly set intercom2N Helios IP Security Relay
®
security output; refer to the . Make sure2N
®
Helios IP Configuration Manual
that one LED at least is on or flashing.
Press and hold the Reset button for 5 seconds to2N Helios IP Security Relay
®
put the device in the programming mode (both the red and green LEDs are
flashing).
Activate the intercom switch using the keypad, telephone, etc. The first code sent
from the intercom will be stored in the memory and considered valid. After code
initialisation, the will pass into the operational2N Helios IP Security Relay
®
mode (green LED flashing).