TEST RESULTS
Table 2 summarizes the results of the intelligibility testing. Sample results are also shown in the bar
graphs, below.
System
Noise
Reduction
Setting
Low Noise
<25dBA
Medium Noise
(70dBA)
High Noise
(80dBA)
3M™ C1060
(Analog)
Off 0.86 0.55 0.26
Competitive
Digital
Off 0.84 0.58 0.28
3M™ C1060
(Analog)
On (-6dB) 0.76 0.69 0.49
Competitive
Digital
On (-6dB) 0.82 0.71 0.46
Table 2: Speech Intelligibility Index (STI) Test Results, Inbound