3M C1060 - Troubleshooting C960 Inbound Noise or Interference

3M C1060
90 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Tips and Tricks
When troubleshooting inbound noise or interference problems on the C960 Intercom System try
removing the outside microphone by disconnecting the top 4-position connector from the Base Station
momentarily, during the interference.
If the all the noise disappears, the problem may be solved by improving the wire shielding or the
acoustic isolation of the microphone.
If the noise remains, try changing channels or the Lane jumper, L3 on the Base Station. Then re-
program the headsets. You may need to locate and remove other sources of 900 MHz interference.