EasyManua.ls Logo

3M PELTOR ComTac 7 - PAIRING AND CONNECTING THE SYSTEM; Pairing RCU-300 to SCU-300

3M PELTOR ComTac 7
41 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
23
4.7. TO POWER ON THE SCU-300
If the SCU-300 was previously connected to the TEP-300 or
ComTac™ VII, the devices will connect automatically when
within range of the SCU-300 and devices are powered on.
1. TheusermustrstemployTEP-300and/ortheComTac™
VII. Refer to the User Instructions of those products for
start-up instructions.
NOTE: The SCU-300 must be positioned correctly during
startup to correctly pair with each device. Refer to “4.3. To
ttheSCU-300”.
2. Press and hold the On/Off/Menu button on the SCU-300
for ~3 seconds.
ON ~ 3 sec
~ 2 secOFF
3. The TEP-300 and/or the ComTac™ VII will indicate
pairing.
2 short beeps, indicates a successful pairing to the
SCU-300.
3 long beeps, indicates the NFMI link is lost.
Beep Beep
Beeeep Beeeep Beeeep
Note: Beeping sounds only occur if the headset has
previously been paired with the SCU-300.
4. If pairing fails, check proper SCU-300 placement. If
problem persists, press the On/Off/Menu button on the
SCU-300 for ~10 seconds or until 2 short beeps are heard
in TEP-300 and/or the ComTac™ VII.
4.8. TO POWER ON THE RCU-300
1. Short press the + button to power on the RCU-300.
ON
2. Press any button to wake up the RCU-300 if it has gone
into sleep mode.
EN
5. TO PAIR AND CONNECT THE SYSTEM
5.1. TO PAIR THE RCU-300 TO THE SCU-300
RCU-300 uses Bluetooth
®
Low Energy communication.
Bluetooth
®
Low Energy is a short-range wireless
communication protocol. It is designed for long battery life.
Therangeis≈50cm/20in.
Pairing the RCU-300 to the SCU-300 requires the use of the
TEP-300 or ComTac™ VII headset. Refer to those products’
User Instructions for use information.
To receive auditory prompts when powering on the SCU-300,
theusermustrstemploytheComTac™VIIheadsetor
TEP-300 earplugs. If the SCU-300 was previously connected
to the TEP-300 or ComTac™ VII, the devices will connect
automatically when within range of the SCU 300 and devices
are powered on.
1. Power on the TEP-300 and/or ComTac™
VII. Refer to “4.5.
To power on the TEP-300” and/or “4.6. To power on the
ComTac™ VII”.
NOTE: Make sure the TEP-300 and/or ComTac™
VII are
correctlytted.RefertototheUserInstructionsforthose
products.
2. Power on SCU-300. Refer to “4.7. To power on the
SCU-300”.
3. Power on the RCU-300. Refer to “4.8. To power on the
RCU-300”.
4. Short press the power button on the SCU-300 to access
the menu.
~ 0.5 sec
5. Short press the - button to move forward in the menu
system until the audio message indicates the “Advanced
settings” sub menu.
6. Select “Advanced settings” with the + button.
EN