Rather than using the immersion heater to boost hot water, an external heat source e.g. a boiler can be used by making use of the
multi-function relay wired to the boiler hot water controls.
I
t may be desirable to use a de-stratification pump to mix the cooler water at the bottom of the cylinder with the hotter water at the
top, this allows a top mounted immersion heater to heat all of the water in the cylinder.
11
Boiler Hot Water Boost
BOILER HW CALL
Volt-free contact
Connect to boiler wiring
240V AC MAINS SUPPLY
From 16A MCB or
13A fused outlet
IMMERSION HEATER
Max. Load 3kW
CLAMP
Install onto incoming mains
Live cable to building
COMMS LINK
For linking several
ImmerSUN devices
ISOLATOR
Must be double-pole
5V GD AB CT CT
COMMS
RELAY MAINS
NOCNC
E
E
N LN LH
CLAMPPWR
De-strat Pump
CLAMP
Install onto incoming mains
Live or Neutral cable to building
240V AC MAINS SUPPLY
From 16A MCB or
13A fused outlet
COMMS LINK
For linking several
ImmerSUN devices
5V GD AB CT CT
COMMS
RELAY MAINS
NOCNC
E
E
N LN LH
CLAMPPWR
IMMERSION HEATER
Max. Load 3kW
DE-STRAT PUMP
With 3A fused isolator
ISOLATOR
Must be double-pole