37
11 Sizing data (continued)
Indirect Plate Water Heater Installation & Service Manual
NOTE: Highlighted items are limited by the maximum ow velocity through the piping.
Table 11G Sizing Chart _ 40 - 160
DOMESTICWATERINLET‐
OUTLET(°F)
BOILERWATERINLETTEMP
(°F)
APWMODEL
DOMESTIC BOILER
FLOW(GPM) PRESSURELOSS(PSI) MAX.FLOW(GPM)
OUTLETTEMP(°F)
MAX.PRESSURELOSS(PSI)
151 8
APW030DW 14 1 75 141 8
40‐160
165
APW015DW 8 1 75
APW050DW 20 1 75
APW090DW 39 1 160 135 9
132 8
APW070DW 30.5 1 130 136 14
APW120DW 58 1 225 133 15
APW105DW 48 1 225 138 15
8
APW030DW 18 1 75 140 8
170
APW015DW 10.5 1 75 152
APW050DW 25 1 75
APW090DW 49.5 1 160 131 9
128 8
APW070DW 38.5 1 130 133 14
APW120DW 72 1 225 130 15
APW105DW 61 1 225 136 15
8
APW030DW 24 1 75 140 8
180
APW015DW 14.5 1 75 156
APW050DW 33 1 75
APW090DW 65 1 160 129 9
125 8
APW070DW 51 2 130 131 14
APW120DW 95 1 225 127 15
APW105DW 81 1 225 135 15
8
APW030DW 29.5 1 75 141 8
190
APW015DW 18 1 75 160
APW050DW 40 2 75
APW090DW 78 1 160 129 9
123 8
APW070DW 62 2 130 130 14
APW120DW 114 1 225 127 15
APW105DW 98 1 225 135 15
8
APW030DW 34.5 1 75 142 8
200
APW015DW 21.5 1 75 164
APW050DW 46 2 75
APW090DW 90 1 160 129 9
123 8
APW070DW 71.5 3 130 131 14
APW120DW 131 2 225 127 15
APW105DW 114 1 225 136 15
8
APW030DW 39.5 1 75 144 8
210
APW015DW 25 1 75 168
APW050DW 52 2 75
APW090DW 102 1 160 130 9
123 8
APW070DW 80 3 130 132 14
APW120DW 149 2 225 127 15
APW105DW 128 1 225 138 15
220
APW015DW 28 1 75 173
APW050DW 58 2 75
APW090DW 114 1 160 130
122
140 15
8
APW030DW 44 2 75 146 8
9
8
APW070DW 80 3 130 142 14
APW120DW 160 2 225 130 15
APW105DW 143 2 225