EasyManua.ls Logo

A.O. Smith DEL - ROUGH-IN DIMENSIONS; DEL Series Physical Dimensions; DEN Series Physical Dimensions; RECOVERY CAPACITIES

A.O. Smith DEL
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
ROUGH-IN DIMENSIONS
RECOVERY CAPACITIES
Element U.S. Gallons/Hr and Litres/Hr at TEMPERATURE RISE INDICATED
Wattage INPUT F° 36F° 40F° 54F° 60F° 72F° 80F° 90F° 100F° 108F° 120F° 126F°
(Upper/Lower) KW C° 20C° 22.2C° 30C° 33.3C° 40C° 44.4C° 50C° 55.5C° 60C° 66.6C° 70C°
NON-SIMULATANEOUS OPERATION
/1500 GPH 17 15 11 10 8 8 7 6 6 5 5
1.5 LPH 64 58 43 38 32 29 26 23 21 19 18
/2000 GPH 23 20 15 14 11 10 9 8 8 7 6
2.0 LPH 85 77 57 51 43 38 34 31 28 26 24
/2500 GPH 28 25 19 17 14 13 11 10 9 8 8
2.5 LPH 107 96 71 64 53 48 43 38 36 32 30
3000/3000 GPH 34 30 23 20 17 15 14 12 11 10 10
3.0LPH1281158577645851 46433837
4000/4000 GPH 45 41 30 27 23 20 18 16 15 14 13
4.0 LPH 170 153 114 102 85 77 68 61 57 51 49
4500/4500 GPH 51 46 34 30 25 23 20 18 17 15 14
4.5 LPH 192 173 128 115 96 86 77 69 64 58 55
5000/5000 GPH 56 51 38 34 28 25 23 20 19 17 16
5.0 LPH 213 192 142 128 107 96 85 77 71 64 61
6000/6000 GPH 68 61 45 41 34 30 27 24 23 20 19
6.0 LPH 256 230 170 153 128 115 102 92 85 77 73
SIMULATANEOUS OPERATION
3000/3000 GPH 68 61 45 41 34 30 27 24 23 20 19
6 LPH 256 230 170 153 128 115 102 92 85 77 73
4000/4000 GPH 90 81 60 54 45 41 36 32 30 27 26
8 LPH 341 307 227 205 170 153 136 123 114 102 97
4500/4500 GPH 101 91 68 61 51 46 41 36 34 30 29
9 LPH 384 345 256 230 192 173 153 138 128 115 110
5000/5000 GPH 113 101 75 68 56 51 45 41 38 34 32
10 LPH 426 384 284 256 213 192 170 153 142 128 122
6000/6000 GPH 135 122 90 81 68 61 54 49 45 41 39
12 LPH 511 460 341 307 256 230 205 184 170 153 146
Recovery capacities at 100° F rise equal: for non-simultaneous element operation = 4.1 gal. x KW of one element; for simultaneous element operation
= 4.1 gal. x 2/3 KW of both elements. For other rises multiply element KW as previously explained by 410 and divide by temperature rise. Full load current for single
phase = total watts : voltage.
ROUGH-IN DIMENSIONS
Approx.
Models No. of Tank Capacity A B C D Shipping Weight.
Dimensions Elements US Gals. Litres inches mm inches mm inches mm inches mm Lbs. Kg.
DEL-6 1 6 23 15 1/2 394 14 1/4 362 11 279 - - 35 15.9
DEL-10 1 10 38 18 1/4 464 18 457 12 1/2 318 - - 54 24.5
DEL-15 1 15 57 26 660 18 457 20 1/2 521 - - 58 26.3
DEL-20 1 20 76 22 1/4 565 21 3/4 552 15 3/8 391 - - 73 33.1
DEL-30 2 30 114 30 7/8 784 21 3/4 552 24 1/8 613 8 203 100 45.4
DEL-40 2 40 151 32 1/4 819 24 610 25 9/16 649 8 203 125 56.7
DEL-50 2 50 189 32 1/4 819 26 1/2 673 25 1/8 638 8 203 166 75.3
DEN-30 1 30 114 34 1/2 876 20 1/2 521 - - 8 203 98 44.5
DEN-40 2 40 151 45 1/8 1146 20 1/2 521 - - 8 203 113 51.3
DEN-52 2 50 189 54 7/8 1394 20 1/2 521 - - 8 203 131 59.4
DEN-66 2 66 250 60 3/4 1543 21 3/4 552 - - 8 203 176 79.8
DEN-80 2 80 303 59 3/8 1508 24 610 - - 8 203 211 95.7
DEN-120 2 119 450 62 7/16 1586 29 3/8 746 - - 8 203 326 147.9