ACH580-01 PxR, UL Type 1/12
Frame R3/R4
Base drive replacement instructions
Purpose or Scope
The following are the instructions for replacing an ACH580-01 UL Type 1 (Frames R3 & R4)
drive in PxR enclosures.
Equipment required*:
– Replacement drive (see note below)
– T20 bit
– T25 bit
– T30 bit
– PZ2 bit
– PZ3 bit
– Torque wrench
– Zip ties
Basic overview of steps
– Back-up drive parameters (if you can)
– Remove power and verify after 5 minutes
– Remove covers
– Disconnect all wiring
– Remove drive
– Prepare replacement drive
– Remove conduit assembly
– Install in reverse order
– Check connections
– Power drive
– Reprogram and test
Notes and cautions
CAUTION! Review complete safety and electrical considerations prior
to replacing the drive. See ACH580 IOM (3AXD50000049127).
CAUTION! Two people are recommended for this job. The drive is
heavy and can fall, causing property damage and injury.
NOTE: UL Type 12 drives require a UL Type 12 replacement drive,
UL Type 1 drives are not allowed as substitutes for UL Type 12.
* Not all of these tools are needed for each frame size.