Emax
Installation, service and
maintenance instructions
for low voltage air circuit-breakers
Installation and service
instructions
1SDH000460R0002 L2778

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ABB E3S 25 and is the answer not in the manual?

ABB E3S 25 Specifications

General IconGeneral
BrandABB
ModelE3S 25
CategoryCircuit breakers
LanguageEnglish

Summary

Checking on Receipt, Storage, and Installation

Electrical Connections and Wiring

Connections to the Power Circuit

Details on connecting the circuit-breaker to the power circuit, including terminal shapes and busbar positioning.

Putting into Service and Instructions for Use

General Procedures for Putting into Service

Checks and procedures for putting the circuit-breaker into service, including preparatory operations and voltage checks.

Circuit-Breaker Closing and Opening Procedures

Manual and electrical procedures for loading springs, closing, and opening the circuit-breaker.

Racking-in/out Operation

Detailed steps for safely racking the circuit-breaker in and out of its position, including notes on positions.

Maintenance Procedures

Maintenance Warnings

General warnings and mandatory procedures to follow before performing any maintenance work.

Maintenance Operations

Detailed maintenance steps including preliminary operations, general inspection, and contact wear checking.

Operating Anomalies and Troubleshooting

Measures for Operating Anomalies

Troubleshooting guide for circuit-breaker anomalies, listing possible causes and remedies.

Protection Releases - General Notes

Safety Notes

General safety warnings regarding the use, handling, and potential hazards of the device.

PR121/P Other Functions, Service, and Interface

Putting into Service

Steps for putting the PR121/P into service, including connections and initial checks.

Trip Test and Initial Settings

Instructions for trip testing, initial settings, and changing protection functions.

PR121/P Alarms, Signals, and Troubleshooting

Troubleshooting PR121/P Unit

Table of typical service conditions, possible causes, and suggested solutions for troubleshooting.

SACE PR122/P Release - Identification and Specifications

Summary Tables for Protections and Measurements

Summary tables of PR122/P protection settings, ranges, tolerances, and measurements.

PR122/P Putting into Service, Interface, and Operation

PR122/P Alarms, Signals, and Troubleshooting

Troubleshooting PR122/P Unit

Table of typical service conditions, possible causes, and suggested solutions for troubleshooting.

SACE PR123/P Release - Identification and Specifications

Protection Functions Description

Detailed description of protection functions L, S, D, I, G, U, OT, UV, OV, RV, RP, UF, OF.

Summary Table of Protection Settings

Comprehensive summary table of PR123/P protection settings, ranges, and tolerances.

PR123/P Putting into Service, Interface, and Operation

Putting into Service Procedures

Steps for putting the PR123/P into service, including connections and initial checks.

Operating Instructions and Service

Instructions for operating the PR123/P unit, including menu navigation and protection settings.

PR123/P Alarms, Signals, and Troubleshooting

Troubleshooting PR123/P Unit

Table of typical service conditions, possible causes, and suggested solutions for troubleshooting.

Related product manuals