Questions and Answers

  • J
    Jessica ChangSep 3, 2025
    What to do if lubricating oil pressure is too low in ABB Battery Charger?
    • G
      gabrielpearsonSep 3, 2025
      If the lubricating oil pressure is too low in your ABB Battery Charger, it could be due to a heavily contaminated oil filter, which needs cleaning. Another cause could be a defective oil pump in the lubricating system, which should be checked or replaced. A wrong reading on the manometer may also be the reason, in this case you should replace the manometer. Finally, it could be due to a rotor axial clearance being too large, in which case you should contact an ABB Turbocharging Service Station.
  • S
    Sarah HowellSep 2, 2025
    What to do if ABB Battery Charger is surging?
    • G
      Gregory HarmonSep 2, 2025
      If your ABB Battery Charger is experiencing turbocharger surging, the guard in front of the turbocharger may be contaminated or damaged, requiring cleaning or replacement. Alternatively, the filter silencer or diffuser could be contaminated, in which case you should clean it. Another possibility is a contaminated cooler, which would also need cleaning.
  • P
    Paige ThomasSep 1, 2025
    Why is the exhaust gas temperature too high in my ABB Battery Charger?
    • J
      Jennifer ThompsonSep 1, 2025
      If the exhaust gas temperature of your ABB Battery Charger is too high, it could be due to several reasons. The injection system might be malfunctioning, requiring repair or manufacturer contact. There might be air starvation caused by a filter silencer clogged with dirt, which you should clean. High exhaust counterpressure could be the cause, necessitating cleaning or repair of the boiler or exhaust silencer. A contaminated cooler, low cooling water volume (top up the water), high cooling water entry temperature (inspect/clean the cooling system), or inadequate ventilation (improve ventilation) could also be responsible.
  • A
    Allison KochAug 31, 2025
    What to do if ABB Industrial Equipment is vibrating?
    • T
      Tonya VargasSep 1, 2025
      If your ABB Industrial Equipment is vibrating, it may be due to rotor unbalance. In this situation, contact an ABB Turbocharging Service Station.
  • D
    David SingletonAug 31, 2025
    What to do if rotating parts of ABB Industrial Equipment are rubbing?
    • C
      Christina HeathAug 31, 2025
      Rubbing of rotating parts in ABB Industrial Equipment can be normal behavior and not a malfunction. If there is any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted.
  • T
    toddchloeAug 30, 2025
    How to deal with rubbing of rotating parts in ABB Industrial Equipment?
    • C
      Cynthia RodgersAug 30, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, contact an ABB Turbocharging Service Station if there is any doubt about the extent of the rubbing. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • J
    jamesbrendaAug 29, 2025
    Why is my ABB HT562167 experiencing a sluggish start-up?
    • G
      Gregory BowenAug 29, 2025
      A sluggish start-up in ABB Industrial Equipment can occur due to several reasons. It might be caused by a contaminated turbocharger, in which case you should clean it. Alternatively, it could be due to a damaged bearing, requiring you to contact an ABB Turbocharging Service Station. Other possible causes are a rubbing rotor or a foreign object in the turbocharger.
  • B
    Bonnie WilsonAug 28, 2025
    How to fix sluggish start-up of ABB Industrial Equipment?
    • S
      Sheila AndersonAug 28, 2025
      A sluggish start-up of your ABB Industrial Equipment can occur if the turbocharger is contaminated. In this case, clean the turbocharger. Another possible cause is a damaged bearing. If the bearing is damaged, contact an ABB Turbocharging Service Station.
  • C
    Carrie HebertAug 27, 2025
    What to do if ABB Industrial Equipment has vibrations?
    • B
      Brianna HillAug 27, 2025
      If your ABB Industrial Equipment is experiencing vibrations, it could be due to a rotor unbalance. In this case, contact an ABB Turbocharging Service Station. Vibrations may also be caused by a damaged turbine or compressor, or a damaged bearing.
  • O
    owensdanielAug 26, 2025
    What to do if ABB HT562167 has rubbing of rotating parts?
    • J
      Jennifer SharpAug 27, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.