Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS52-F32 HT563889
n
Mmax
865 t
Mmax
710
n
Bmax
822 t
Bmax
680
1/s °C
SOLD06 00250 12 50 50
Year 2016
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS52-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • S
    Stephanie MunozAug 30, 2025
    What to do if ABB Industrial Equipment has rubbing of rotating parts?
    • C
      Corey ThomasAug 31, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.
  • A
    Alyssa ColonSep 8, 2025
    How to fix a sluggish start-up on ABB Battery Charger?
    • J
      Jill HolmesSep 8, 2025
      If your ABB Battery Charger has a sluggish start-up, it could be due to a contaminated turbocharger (clean it) or a damaged bearing (contact an ABB Turbocharging Service Station).
  • C
    Connie PattersonAug 29, 2025
    Why is my ABB HT563889 start-up sluggish?
    • K
      Kevin BakerAug 29, 2025
      A sluggish start-up of your ABB Industrial Equipment can be due to several reasons. It might be caused by a contaminated turbocharger, which requires cleaning. Other potential causes include a damaged bearing, a rubbing rotor, or a foreign object present in the turbocharger.
  • A
    alyssarobinsonSep 23, 2025
    What causes sluggish start-up in ABB Battery Charger?
    • T
      Thomas FoxSep 23, 2025
      A sluggish start-up in your ABB Battery Charger could be due to: * A contaminated turbocharger, which requires cleaning. * A damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • M
    Matthew AnthonySep 9, 2025
    Why is the exhaust gas temperature too high in my ABB Industrial Equipment?
    • J
      Justin GraySep 9, 2025
      High exhaust gas temperature in your ABB Industrial Equipment can stem from several issues. It could be due to a malfunctioning injection system, which requires repair or consultation with the manufacturer. Other potential causes include air starvation from a filter silencer clogged with dirt (clean it), high exhaust counterpressure (clean or repair the boiler or exhaust silencer), a contaminated cooler (clean it), insufficient cooling water volume (top up the water), high cooling water entry temperature (inspect/clean the cooling system), or inadequate ventilation (improve the ventilation).
  • H
    hartmanjasonSep 13, 2025
    How to resolve vibrations in ABB Industrial Equipment?
    • D
      Daniel MurphySep 13, 2025
      Vibrations in your ABB Industrial Equipment may be caused by rotor unbalance. Contact an ABB Turbocharging Service Station to resolve this issue.
  • A
    Alexander BuchananSep 18, 2025
    What causes reduction in speed in ABB Battery Charger and how to fix it?
    • M
      Michael WallaceSep 18, 2025
      A reduction in speed in your ABB Battery Charger can be caused by: * Heavy contamination of the turbine, which can be resolved by cleaning it. * Damaged rotor components or bearing, requiring you to contact an ABB Turbocharging Service Station. * Defects such as leaks in the exhaust gas pipes or charge air ducts, which require repairs.
  • A
    Amber SheppardAug 27, 2025
    How to deal with rubbing of rotating parts in ABB HT563889?
    • J
      John DawsonAug 27, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, contact an ABB Turbocharging Service Station if there is any doubt about the extent of the rubbing. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • A
    Andrew VargasAug 26, 2025
    Why is my ABB HT563889 Industrial Equipment vibrating?
    • C
      carmen03Aug 26, 2025
      Vibrations in your ABB Industrial Equipment can occur due to several reasons. It might be caused by rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. Vibrations can also arise from a damaged turbine or compressor, or a damaged bearing.
  • C
    Christine WheelerAug 25, 2025
    What to do if ABB Industrial Equipment rotating parts are rubbing?
    • B
      bennettstephanieAug 26, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you have any doubt about the extent of rubbing, then an ABB Turbocharging Service Station must be contacted.

ABB HT563889 Specifications

General IconGeneral
BrandABB
ModelHT563889
CategoryIndustrial Equipment
LanguageEnglish