Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F32 HT572308
n
Mmax
1029 t
Mmax
680
n
Bmax
978 t
Bmax
650
1/s °C
SOLD08 00180 12 60 60
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • V
    vlaneAug 26, 2025
    What to do if my ABB charger is surging?
    • A
      anthonymartinAug 26, 2025
      If your ABB turbocharger is surging, it could be due to: * A contaminated or damaged guard in front of the turbocharger: Clean or replace it. * A contaminated filter silencer or diffuser: Clean it. * A contaminated cooler: Clean it. * A blocked charge air duct.
  • E
    evansjosephAug 26, 2025
    Why is there a reduction in speed in my ABB charger?
    • W
      William MitchellAug 26, 2025
      A reduction in speed in your ABB charger can stem from: * Defects of connected cylinders when pulse charging: Contact the enginebuilder. * Heavy contamination of the turbine: Clean it. * Damaged rotor components or bearing: Contact an ABB Turbocharging Service Station. * Defects such as leaks in the exhaust gas pipes or charge air ducts: Make repairs.
  • R
    Roberto ParkerAug 25, 2025
    Why is the charge air pressure too high in my ABB charger?
    • T
      thomasmarkAug 26, 2025
      If the charge air pressure is too high in your ABB charger, it may be due to: * A malfunctioning injection system: Repair it or contact the manufacturer. * A poorly adjusted injection system: Correct it. * Engine performance higher than expected: Check engine performance. * Manometer display wrong: Replace the manometer.
  • M
    Mark ReyesAug 25, 2025
    Why is the charge air pressure too low in my ABB charger?
    • R
      Rhonda RileyAug 25, 2025
      If the charge air pressure is too low in your ABB charger, several factors could be responsible: * Air receiver leaking: Make repairs. * Gas piping between the engine and the turbine leaking. * Poorly adjusted injection system: Correct it. * Poorly adjusted valve control. * Manometer display wrong: Replace the manometer. * Line to manometer leaking: Repair the leak. * Contaminated filter silencer: Clean it because it causes excessive pressure loss. * Damaged compressor/turbine: Contact an ABB Turbocharging Service Station. * High exhaust counterpressure: Clean or repair the boiler or exhaust silencer.
  • E
    Erin SheltonSep 4, 2025
    What to do if ABB Industrial Equipment has charge air pressure too high?
    • R
      Robert LarsonSep 4, 2025
      If the charge air pressure is too high, it could be due to a malfunctioning or poorly adjusted injection system, so repair or correct it. The engine performance might also be higher than expected, so check engine performance. The manometer display might be providing a wrong reading, so replace the manometer.
  • M
    Mark BellSep 7, 2025
    What causes charge air pressure to be too high in ABB HT572308?
    • M
      Miguel EdwardsSep 8, 2025
      If the charge air pressure of your ABB Industrial Equipment is too high, the injection system may be malfunctioning, so repair it or contact the manufacturer. Also, correct a poorly adjusted injection system. Check engine performance if the engine performance is higher than expected. Replace the manometer if the display is wrong.
  • M
    matthewyoungSep 7, 2025
    How to resolve turbocharger surging in ABB Industrial Equipment?
    • C
      Carlos HansonSep 7, 2025
      If the turbocharger of your ABB Industrial Equipment is surging, it could be due to a contaminated or damaged guard, so clean or replace it. Also, clean the filter silencer or diffuser if they are contaminated. The cooler might be contaminated, so clean it.
  • M
    michele94Sep 6, 2025
    What to do if the charge air pressure is too low in ABB Industrial Equipment?
    • R
      Robert SantosSep 7, 2025
      If your ABB Industrial Equipment experiences charge air pressure that is too low, several factors could be responsible. You can repair any leaks in the air receiver or correct a poorly adjusted injection system. Additionally, you should replace the manometer if the display is wrong, or repair the leak if the line to the manometer is leaking. Clean the filter silencer if it is contaminated, causing excessive pressure loss. Finally, clean or repair the boiler or exhaust silencer if the exhaust counterpressure is too high.
  • R
    richardmitchellSep 6, 2025
    Why is the exhaust gas temperature too high in my ABB HT572308 Industrial Equipment?
    • D
      david85Sep 6, 2025
      If the exhaust gas temperature of your ABB Industrial Equipment is too high, it could be due to several reasons. The injection system may be malfunctioning, so repair it or contact the manufacturer. Another cause may be air starvation, so clean the filter silencer if it's clogged with dirt. You can also clean the boiler or exhaust silencer if the exhaust counterpressure is too high. Also, clean the cooler if it's contaminated. Top up the water if the cooling water volume is too low. Inspect or clean the cooling system if the entry temperature of cooling water is too high. Improve the ventilation if it is inadequate.
  • L
    Lisa SimsSep 6, 2025
    How to fix a sluggish start-up on ABB HT572308 Industrial Equipment?
    • J
      jeffrey16Sep 6, 2025
      A sluggish start-up in ABB Industrial Equipment can be due to several reasons. The turbocharger may be contaminated and needs cleaning. Alternatively, there could be a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.

ABB HT572308 Specifications

General IconGeneral
Breaking Capacity6 kA
Poles3
MountingDIN Rail
TypeCircuit Breaker
Rated Voltage400V AC
Mechanical Life20000 cycles
Electrical Life10000 cycles