Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS44-F32 HT575175
n
Mmax
1231 t
Mmax
680
n
Bmax
1169 t
Bmax
650
1/s °C
00120 12 50 50
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS44-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • S
    Shawn ThomasSep 12, 2025
    How to troubleshoot a sluggish start-up in ABB HT575175 Industrial Equipment?
    • J
      Jermaine MendozaSep 12, 2025
      If your ABB Industrial Equipment has a sluggish start-up, it could be due to: * A contaminated turbocharger; clean it. * A damaged bearing; contact an ABB Turbocharging Service Station.
  • J
    Jimmy BlankenshipSep 12, 2025
    Why is there a reduction in speed in my ABB HT575175?
    • N
      Nicole JonesSep 12, 2025
      If you notice a reduction in speed in your ABB Industrial Equipment, it could be caused by: * Heavy contamination of the turbine; clean it. * Damaged rotor components or bearing; contact an ABB Turbocharging Service Station.
  • D
    Daniel LiuSep 9, 2025
    Why is the charge air pressure too high in my ABB HT575175?
    • J
      Jeff YoungSep 9, 2025
      If the charge air pressure is too high in your ABB Industrial Equipment, it could be due to: * A malfunction in the injection system; repair it or contact the manufacturer. * The injection being misaligned; set it correctly.
  • L
    Laura CobbSep 8, 2025
    What causes the charge air pressure to be too low in ABB HT575175 Industrial Equipment?
    • A
      Alyssa ScottSep 8, 2025
      If the charge air pressure is too low in your ABB Industrial Equipment, it might be due to: * A leaky air receiver; repair it. * A maladjusted injection system; correct it. * A faulty manometer display; replace the manometer. * A dirty filter silencer causing excessive pressure loss; clean it.
  • K
    Kenneth ChavezSep 7, 2025
    Why is the lubricating oil pressure too low in my ABB HT575175 Industrial Equipment?
    • K
      Kathleen JonesSep 7, 2025
      If the lubricating oil pressure is too low in your ABB Industrial Equipment, consider the following: * The oil filter might be heavily contaminated; clean it. * The oil pump in the lubricating system may be defective; check or replace it. * The manometer display could be wrong; replace the manometer. * The rotor axial clearance might be too large; contact an ABB Turbocharging Service Station.
  • A
    Andrew ColeAug 23, 2025
    Why is my ABB Industrial Equipment vibrating?
    • J
      Joshua MillerAug 23, 2025
      Vibrations in your ABB Industrial Equipment can stem from several issues: an unbalanced rotor, a damaged turbine or compressor, or a damaged bearing.
  • A
    aliciacortezSep 5, 2025
    Why is the exhaust gas temperature too high in my ABB HT575175 Industrial Equipment?
    • C
      ccollinsSep 5, 2025
      If the exhaust gas temperature is too high in your ABB Industrial Equipment, it could be due to several reasons: * The injection system might be malfunctioning; in this case, repair it or contact the manufacturer. * There might be air starvation, possibly caused by a filter silencer clogged with dirt; clean it. * The cooler could be dirty; clean it. * The cooling water volume might be insufficient; top up the water. * The entry temperature of the cooling water could be too high; inspect or clean the cooling system. * There may be inadequate ventilation; improve the ventilation.
  • S
    Steven RogersSep 4, 2025
    Why is my ABB HT575175 start-up sluggish?
    • T
      Theresa VaughnSep 4, 2025
      A sluggish start-up of your ABB Industrial Equipment can be attributed to several factors. The turbocharger may be contaminated and needs cleaning. Alternatively, there could be a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other possible causes include a rubbing rotor or a foreign object present in the turbocharger.
  • G
    Gregory JacksonSep 3, 2025
    How to deal with rubbing of rotating parts in ABB HT575175 Industrial Equipment?
    • R
      Richard WrightSep 3, 2025
      If you notice rubbing of rotating parts in your ABB Industrial Equipment, and you have any doubt about the extent of the rubbing, then an ABB Turbocharging Service Station must be contacted. Also, have a dimension check carried out by an ABB Turbocharging Service Station.
  • E
    Emily LoweSep 2, 2025
    What to do if ABB HT575175 Industrial Equipment has a sluggish start-up?
    • T
      Tracy VaughanSep 2, 2025
      A sluggish start-up of your ABB Industrial Equipment may be due to a contaminated turbocharger, in which case you should clean it. It could also be caused by a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other causes may include a rubbing rotor or a foreign object in the turbocharger.