Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F32 HT579537
n
Mmax
1029 t
Mmax
680
n
Bmax
978 t
Bmax
650
1/s °C
SOLD08 00180 12 60 60
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • D
    Devin HopkinsSep 3, 2025
    What to do if ABB HT579537 Industrial Equipment has charge air pressure too low?
    • T
      Tammy MarquezSep 3, 2025
      If the charge air pressure is too low, there could be several reasons. The air receiver or the gas piping between the engine and the turbine might be leaking. A poorly adjusted injection system also can cause this issue, so correct it. The manometer display might be providing a wrong reading, so replace the manometer, or the line to the manometer might be leaking, so repair the leak. A contaminated filter silencer causing excessive loss of pressure can also be the reason, so clean it. In some cases, the compressor/turbine might be damaged, which requires contacting an ABB Turbocharging Service Station. High exhaust counterpressure can also cause low charge air pressure, so clean or repair the boiler or exhaust silencer.
  • F
    Frank JonesAug 25, 2025
    Why is the charge air pressure too low in my ABB charger?
    • M
      mark32Aug 25, 2025
      If the charge air pressure is too low in your ABB charger, several factors could be responsible: * Air receiver leaking: Make repairs. * Gas piping between the engine and the turbine leaking. * Poorly adjusted injection system: Correct it. * Poorly adjusted valve control. * Manometer display wrong: Replace the manometer. * Line to manometer leaking: Repair the leak. * Contaminated filter silencer: Clean it because it causes excessive pressure loss. * Damaged compressor/turbine: Contact an ABB Turbocharging Service Station. * High exhaust counterpressure: Clean or repair the boiler or exhaust silencer.
  • N
    Nancy ClayAug 25, 2025
    Why is the charge air pressure too high in my ABB charger?
    • V
      Victor LopezAug 26, 2025
      If the charge air pressure is too high in your ABB charger, it may be due to: * A malfunctioning injection system: Repair it or contact the manufacturer. * A poorly adjusted injection system: Correct it. * Engine performance higher than expected: Check engine performance. * Manometer display wrong: Replace the manometer.
  • E
    Edwin AllenSep 10, 2025
    Why is my ABB HT579537 having a sluggish start-up?
    • T
      Timothy SanchezSep 10, 2025
      If your ABB Industrial Equipment experiences a sluggish start-up, it could be due to a few reasons. The turbocharger might be contaminated and need cleaning. Alternatively, there may be damage to the bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a rubbing rotor or a foreign object present in the turbocharger.
  • R
    robinsonjamesSep 16, 2025
    What to do if lubricating oil pressure is too low in ABB Marine Equipment?
    • T
      Teresa DaughertySep 17, 2025
      If the lubricating oil pressure is too low, it could be due to several reasons. The oil filter might be heavily contaminated (clean it), the oil pump in the lubricating system could be defective (check / replace it), the manometer display might be wrong (replace the manometer), or the rotor axial clearance might be too large (contact an ABB Turbocharging Service Station).
  • N
    Nicholas HarveySep 6, 2025
    What to do if the charge air pressure is too low in ABB HT579537?
    • L
      Lucas SmithSep 7, 2025
      If your ABB Industrial Equipment experiences charge air pressure that is too low, several factors could be responsible. You can repair any leaks in the air receiver or correct a poorly adjusted injection system. Additionally, you should replace the manometer if the display is wrong, or repair the leak if the line to the manometer is leaking. Clean the filter silencer if it is contaminated, causing excessive pressure loss. Finally, clean or repair the boiler or exhaust silencer if the exhaust counterpressure is too high.
  • H
    hunterjoseAug 31, 2025
    What to do if ABB HT579537 Industrial Equipment has vibration?
    • B
      Brandy JohnsonAug 31, 2025
      If your ABB Industrial Equipment is vibrating, it could be due to rotor unbalance, in which case you should contact an ABB Turbocharging Service Station. Other potential causes include a damaged turbine or compressor, or a damaged bearing.
  • K
    Kristen Murphy DDSSep 22, 2025
    How to fix rubbing rotating parts in ABB HT579537 Industrial Equipment?
    • M
      Mr. Matthew HeathSep 22, 2025
      If the rotating parts of your ABB Industrial Equipment are rubbing, have a dimension check carried out by an ABB Turbocharging Service Station.
  • M
    Michael WestSep 13, 2025
    What to do if ABB HT579537 Industrial Equipment has rubbing of rotating parts?
    • A
      Anita HermanSep 13, 2025
      If you suspect rubbing of rotating parts in your ABB Industrial Equipment, and you're unsure about the extent of the rubbing, it's best to contact an ABB Turbocharging Service Station. They can perform a dimension check to assess the situation.
  • P
    Paula HarrisAug 28, 2025
    What causes fouling of the compressor in my ABB charger?
    • I
      ibauerAug 28, 2025
      Fouling of the compressor in your ABB charger, due to the feeding in of ventilation gases, may result from: * Heavy fouling of the compressor components: Clean compressor. * Material of compressor wheel corroded: Check the fuel and its corrosive components, and change fuel if necessary.