Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F32 HT579537
n
Mmax
1029 t
Mmax
680
n
Bmax
978 t
Bmax
650
1/s °C
SOLD08 00180 12 60 60
Year 2017
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F32
Original Operation Manual

Table of Contents

Questions and Answers

  • J
    Joshua CallahanSep 5, 2025
    Why is there an increase in speed in ABB HT579537 Industrial Equipment?
    • C
      Chad ThomasSep 5, 2025
      An increase in speed could be caused by a heavily contaminated nozzle ring (with 4-stroke application). In this case, contact an ABB Turbocharging Service Station.
  • R
    ramirezadamSep 5, 2025
    How to fix vibrations in ABB HT579537?
    • M
      martin75Sep 5, 2025
      If you are experiencing vibrations, it could be due to rotor unbalance. In this case, contact an ABB Turbocharging Service Station.
  • K
    Kyle JonesSep 4, 2025
    Why is there fouling of the compressor due to the feeding in of ventilation gases in ABB Industrial Equipment?
    • S
      sylvia61Sep 5, 2025
      Fouling of the compressor due to the feeding in of ventilation gases can occur due to heavy fouling of the compressor components, so clean compressor. It can also lead to increased vibrations or compressor blade damage, so correct the feed of ventilation gases according to instructions of enginebuilder. The material of the compressor wheel might be corroded, so check the fuel and its corrosive components, and change fuel if necessary.
  • L
    lmcconnellAug 25, 2025
    Why is the exhaust gas temperature too high in my ABB charger?
    • M
      michellemartinezAug 25, 2025
      If the exhaust gas temperature is too high in your ABB charger, it could be due to several reasons: * A malfunctioning injection system: Repair it or contact the manufacturer. * Air starvation (e.g., a filter silencer clogged with dirt): Clean the filter silencer. * High exhaust counterpressure: Clean or repair the boiler or exhaust silencer. * A contaminated cooler: Clean the cooler. * Low cooling water volume: Top up the water. * High cooling water entry temperature: Inspect or clean the cooling system. * Inadequate ventilation: Improve the ventilation.
  • A
    Angel KempSep 4, 2025
    What to do if ABB Industrial Equipment has turbocharger surging?
    • V
      vkaufmanSep 4, 2025
      If the turbocharger is surging, the guard in front of it may be contaminated or damaged, requiring cleaning or replacement. Another potential cause is a contaminated filter silencer or diffuser, which needs cleaning. Additionally, a contaminated cooler could be the source of the problem, so clean it. A blocked charge air duct also can cause turbocharger surging.
  • D
    Devin HopkinsSep 3, 2025
    What to do if ABB HT579537 Industrial Equipment has charge air pressure too low?
    • T
      Tammy MarquezSep 3, 2025
      If the charge air pressure is too low, there could be several reasons. The air receiver or the gas piping between the engine and the turbine might be leaking. A poorly adjusted injection system also can cause this issue, so correct it. The manometer display might be providing a wrong reading, so replace the manometer, or the line to the manometer might be leaking, so repair the leak. A contaminated filter silencer causing excessive loss of pressure can also be the reason, so clean it. In some cases, the compressor/turbine might be damaged, which requires contacting an ABB Turbocharging Service Station. High exhaust counterpressure can also cause low charge air pressure, so clean or repair the boiler or exhaust silencer.
  • J
    John MilesSep 3, 2025
    Why is there a reduction in speed in ABB Industrial Equipment?
    • D
      Donald JohnsonSep 3, 2025
      A reduction in speed could stem from defects in connected cylinders during pulse charging, in which case you should contact the enginebuilder. Other potential causes include heavy contamination of the turbine (clean it), damaged rotor components or bearing (contact an ABB Turbocharging Service Station), or defects like leaks in the exhaust gas pipes or charge air ducts (make repairs).
  • A
    Andrew SmithSep 2, 2025
    What to do if lubricating oil pressure is too low in ABB HT579537?
    • T
      Tiffany MackSep 2, 2025
      If the lubricating oil pressure is too low, the oil filter may be heavily contaminated and needs cleaning. Alternatively, the oil pump in the lubricating system could be defective and requires checking or replacement. A wrong reading on the manometer display can also cause this issue, so replace the manometer. In some instances, the rotor axial clearance may be too large, which requires contacting an ABB Turbocharging Service Station.
  • A
    Amanda HughesSep 2, 2025
    What to do if the exhaust gas temperature is too high in ABB HT579537?
    • J
      Joshua NolanSep 2, 2025
      If the exhaust gas temperature is too high, several factors could be responsible. The injection system may be malfunctioning, requiring repair or manufacturer contact. Air starvation might be occurring due to a filter silencer clogged with dirt, which needs cleaning. High exhaust counterpressure could be the issue, necessitating cleaning or repair of the boiler or exhaust silencer. Other potential causes include a damaged or eroded turbine (in which case you should contact an ABB Turbocharging Service Station), a contaminated cooler (clean it), low cooling water volume (top up the water), high cooling water entry temperature (inspect/clean the cooling system), or inadequate ventilation (improve the ventilation).
  • C
    Christy DixonSep 1, 2025
    How to fix sluggish start-up in ABB HT579537?
    • B
      brent11Sep 2, 2025
      A sluggish start-up of your ABB Industrial Equipment could be caused by a contaminated turbocharger, which you can resolve by cleaning it. It may also be due to a damaged bearing, in which case you should contact an ABB Turbocharging Service Station. Other potential causes are rubbing rotor or a foreign object in the turbocharger.

ABB HT579537 Specifications

General IconGeneral
Product IDHT579537
TypeMiniature Circuit Breaker
Rated Current16 A
Rated Voltage230/400 V AC
Breaking Capacity6 kA
Poles3
Mechanical Life20000 operating cycles
Electrical Life10000 operating cycles
MountingDIN rail