EasyManua.ls Logo

ABB HT585015 - User Manual

ABB HT585015
132 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Operation Manual
ABB Turbocharging

ABB Turbo Systems Ltd
CH 5401 Baden
Type TPS48-F33 HT585015
n
Mmax
1006 t
Mmax
680
n
Bmax
956 t
Bmax
650
1/s °C
SOLD06 00180 12 50 50
Year 2019
made in Switzerland
Application according to
the Operation Manual
kg
HZTL2412 English
TPS48-F33
Original Operation Manual

Table of Contents

Questions and Answers

  • B
    bsmithSep 4, 2025
    Why is there an increase in speed in my ABB HT585015?
    • S
      Shannon ThomasSep 4, 2025
      An increase in speed in your ABB Industrial Equipment could be due to a heavily contaminated nozzle ring (with 4-stroke application). If this is the case, you should contact an ABB Turbocharging Service Station.
  • N
    Nicole HooperSep 5, 2025
    Why is my ABB HT585015 Industrial Equipment making noises during run-down?
    • S
      Stephanie LewisSep 5, 2025
      If you are experiencing noises during run-down of your ABB Industrial Equipment, it could be due to a contaminated turbocharger, which requires cleaning. Alternatively, it could be caused by a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • C
    Chelsea OwensSep 5, 2025
    Why is the run-down time too short for my ABB HT585015 Industrial Equipment?
    • L
      Lindsey LeeSep 5, 2025
      If the run-down time is too short for your ABB Industrial Equipment, it could be because the turbocharger is contaminated, and cleaning it may solve the problem. Another possibility is a damaged bearing, in which case you should contact an ABB Turbocharging Service Station.
  • W
    William NicholsSep 6, 2025
    What causes reduced fatigue strength in ABB HT585015 compressor wheel?
    • A
      Amy GarnerSep 6, 2025
      If the material of compressor wheel is corroded, causing reduced fatigue strength of the compressor wheel and compressor blade failure in your ABB Industrial Equipment, check the fuel and its corrosive components, and change fuel if necessary.
  • K
    Keith DominguezSep 7, 2025
    What to do if there is no signal from speed sensor in ABB Industrial Equipment?
    • C
      Casey DiazSep 7, 2025
      If you are not getting a signal or the amplitude is poor on your ABB Industrial Equipment, it may be due to a fitting error. The screw plug for the sensor might have been fitted with an additional gasket (copper ring). Remove this gasket when fitting the speed sensor to ensure the correct distance from the sensor tip to the signal-generating sealing disc.

ABB HT585015 Specifications

General IconGeneral
BrandABB
ModelHT585015
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals