EasyManuals Logo

ABB HT596622 User Manual

ABB HT596622
148 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #41 background imageLoading...
Page #41 background image
Operation Manual / A170-M.. - A175-M..
4 Commissioning / 4.2 Inspection procedures
© Copyright 2022 ABB. All rights reserved. HZTL4033_EN Rev.K January 2022
4.2 Inspection procedures
4.2.1 Introduction
Inspection procedures include preventative visual controls, monitoring and measuring work
before and during commissioning. Inspection procedures enable changes to the turbochar-
ger to be detected. Machine damage can be prevented.
4.2.2 Checks before commissioning
Filter mat (if available)
u Check for damage and contamination.
Lubricating system
CAUTION
Contaminated oil
Serious damage to engine or property can be caused by dirt and solid ma-
terial particles in the oil.
u For the initial commissioning phase and after all service work, flush the
complete lubricating system with warm oil.
u Use special running-in filters when running in the engine and after all ser-
vice work on the lubricating system.
u Check that the oil filter is clean before commissioning.
u Check the oil pressure in the oil supply pipes.
4.2.3 Checks after commissioning (engine in idle mode)
Lubricating system
u Check the oil pressure in the oil supply pipes.
u Check oil inlet temperature.
The admissible values are specified in section Oil supply.
Gas, air and oil pipes
u After starting the engine, check all gas, air and oil pipes for leaks.
Page 39 / 146

Table of Contents

Other manuals for ABB HT596622

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB HT596622 and is the answer not in the manual?

ABB HT596622 Specifications

General IconGeneral
BrandABB
ModelHT596622
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals