Operation Manual / TPL85-B14/-B15/-B16
Operation
4
Expected exchange intervals
4.3
Page 41
© Copyright 2016 ABB. All rights reserved.
May 2016 HZTL2491_EN Revision B
Turbocharger part
Operation with HFO
Gas inlet casing 50000 … 100000
Gas outlet casing
50000 … 100000
Nozzle ring 35000 … 50000
Turbine diffuser / cover ring
25000 … 50000
Other casings 100000
Hose / ball valve
(turbine dry cleaning)
18000 … 36000
HFO = heavy fuel oil
Rotor components See the data on the rating plate
Bearings See the data on the rating plate
NOTICE
Information about replacement intervals
The specified values are only guide values and not guaranteed.
They can vary significantly due, for example, to inadequate servicing,
frequent emergency shutdowns and the use of fuel or lubricating oil of
inferior quality.
Expected replacement
intervals [h]
Recommended replace-
ment intervals [h]

Table of Contents