Operation Manual / TPL85-B14/-B15/-B16
Operation
4
Underpressure measurement on filter
silencer
4.5
Page 45
© Copyright 2016 ABB. All rights reserved.
May 2016 HZTL2491_EN Revision B
Underpressure measurement on filter silencer
4.5
A U-tube manometer can be ordered from ABB Turbo Systems for meas-
uring the negative pressure at the filter silencer.
The measurement can be used for the following purposes:
To measure the correction factor for calculating the turbocharger effi-
ciency during the engine acceptance test.
The use of a filter mat on the filter silencer can cause a loss of pres-
sure. A significant pressure loss indicates an increase in dirt build-up
in the filter material.
U-tube manometer on filter silencer (if present)
81000 Filter silencer
81050 U-tube manometer
A
[mm H
2
O] Pressure loss / Pressure difference
4.5