Operation Manual / TPL65-A10 / -A30
6 Troubleshooting / 6.4 Malfunctions when stopping
© Copyright 2020 . All rights reserved. HZTL2482_EN Rev.E March 2020
6.4 Malfunctions when stopping
Noises during run-down
Possible causes Elimination
Turbochar-
ger
Turbocharger contaminated Clean it
Damaged bearing Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger
Run-down time too short
Possible causes Elimination
Turbochar-
ger
Turbocharger contaminated Clean it
Damaged bearing Contact an ABB Turbocharging
Service Station
Rubbing rotor
Foreign object in turbocharger