9 Opening speed and hold open time
Adjust the opening speed.
A slow door is a safe door. The door speed should be set to allow
unhindered access but as slow as is possible..
Säädä aukioloaika (0...60 s) HOLD OPEN -säätimestä.
Kun säädin käännetään alueelle seq”, joka toinen impulssi avaa oven ja joka toinen sulkee sen.
Minimum safe opening and closing times for door of various widths and
weights are summarized in the table.
10 Push&Go
In fully left position Push&Go is set to off.
In fully right position Push&Go function is on. Operator opens the door to adjusted opening
angle and closes the door after a 5 second of hold open time.
Push&Go is functional only when the door is closed. Pushing on a door during its closing cycle
will not activate the Push&Go feature. Push&Go only functions from the closed position.
11 Test the operation
Note! Long hold open time increases the safety of the door.
- Turn mode switch to AUTO.
- Test the operation.
- The door will open to the adjusted opening angle after ve openings.
- If the function is not as desired, turn mode switch to MAN and repeat steps 4...10.
- If doors opening speed or jumper are changed, the door will open to adjusted opening angle
after ve openings.
Resetting operator to factory settings (operator is moved to new door)
- Turn mode switch to OPEN.
- Push TEACH-button brie y. After that push TEACH-button 5 sec. Door open and closed position
information is removed from the memory.
PUSH&GO
min max
SPEED
0
60
HOLD
OPEN
seq
Time (sec)
Door weight (kg)
Door width
(mm)
60 80 100 120
800 2,7 3,2 3,5 3,9
1000 3,4 4,0 4,4 4,8
1200 4,1 4,7 5,3 5,8
1300 4,5 5,1 5,8 6,3