EasyManua.ls Logo

Absaar SL30 - Page 26

Absaar SL30
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UK
26
Table listing the charging power depending on the position of the switches for SL30.
Output voltage (V)
Load current [A]
Position of the load
button
MIN + 1
12
15A
MIN + 2
12
20A
BOOST
12
30A
“Start” position
START
170A
Position of the load
button
MIN + 1
24
16A
MIN + 2
24
22A
BOOST
24
30A
“Start” position
START
170A
AB-SL40
SL40
EN60335-2-29
BATTERY Max 600Ah Min 100Ah
I
boost
40A I
min
17A
START: 250A 3 Second ON / 120 Second OFF
RATED INPUT
RATED OUTPUT
VOLTAGE
230V/50Hz
INTENSITY
2.2/4.3A
FUSE
20A
VOLTAGE
12/24V
INTENSITY
25/27A
FUSE
3X80A
IP20
Disconnect the 220V power outlet before plugging in or unplugging the battery clamps.
IMPORTANT: Explosive gas, always place away from flames, sparks or incandescent bodies and
always ensure that the area is well-ventilated when charging the batteries.
Table listing the charging power depending on the position of the switches for SL40:
Output voltage (V)
Load current [A]
Position of the load
button
MIN + 1
12
17A
MIN + 2
12
25A
BOOST
12
40A
“Start” position
START
250A
Position of the load
button
MIN + 1
24
18A
MIN + 2
24
27A
BOOST
24
40A
“Start” position
START
250A

Related product manuals