AC Pro S-Series 9-12K
Service Manual
Models
AWH09QC-A3DNA3D/I AWH09QC-A3DNA1D/O
AWH12QC-A3DNA3D/I AWH12QC-A3DNA1D/O
AWH09QC-D3DNA3D/I AWH09QC-D3DNA1D/O
AWH12QC-D3DNA3D/I AWH12QC-D3DNA1D/O
(Refrigerant R410A)
Question and Answer IconNeed help?

Do you have a question about the AC Pro AWH12QC-D3DNA3D/I and is the answer not in the manual?

Summary

Function and Control

Remote Control Button Operations

Mode Selection and Operation

Explains how to select and operate different modes (Auto, Cool, Dry, Fan, Heat).

Additional Remote Control Functions

Special Functions and Operation Guide

Brief Description of Modes and Functions

Basic System Modes: Cooling, Drying, Heating, Auto, Fan

Describes Cooling, Drying, Heating, Auto, and Fan modes with their parameters.

Advanced Functions and Operational Features

I FEEL, Compulsory Defrosting, and Refrigerant Recovery

Covers I FEEL, Compulsory Defrosting, and Refrigerant Recovery functions.

Special Functions and Controls

Defrosting Control and Compressor Logic

Explains defrosting conditions and compressor control logic.

Evaporator Frozen Prevention

Explains evaporator frozen prevention function in cooling/dehumidifying modes.

Protection Functions - Part 1

Starting Estimation and Frequency Limiting

Details starting estimation and frequency limiting for protection.

Reducing Frequency and Power Turn-Off

Covers reducing frequency and power turn-off conditions.

Cooling Overload Protection

Details overload protection functions in cooling mode.

Heating Overload Protection

Details overload protection functions in heating mode.

Protection Functions - Part 2

Heating Overload Frequency and Power Controls

Covers heating overload frequency, power controls, and discharge temperature protections.

Discharge Temperature and Current Protections

Explains protections related to discharge temperature and AC electric current.

Protection Functions - Part 3

Voltage Sag and Communication Fault Protection

Details voltage sag and communication fault protection measures.

Module Protection and Overheating

Covers module protection, overheating, and compressor overload protection.

Compressor Overcurrent Protections

Explains compressor overload and phase current overcurrent protections.

Advanced Protection Mechanisms

Compressor Starting-up, Out-of-Step, and Voltage Protections

Covers compressor starting-up, out-of-step, and DC bus voltage protections.

Four-Way Valve, PFC, and Sensor Failure Detection

Details protections for the 4-way valve, PFC, and sensor failures.

1.3 GREE + APP OPERATION MANUAL

Smartphone App Control Overview

Introduces smartphone control via GREE+ app and OS requirements.

Adding the GREE+ App and Wi-Fi Setup

Guides users on downloading the app and setting up Wi-Fi.

Launching the GREE+ App and Account Sign-up

Configuring Wi-Fi Network and Adding AC Unit

Navigating the App Home Screen and Basic Controls

Instructions for returning to the app's home screen and performing basic ON/OFF controls.

Customizing the GREE+ App

App Settings and Unit Naming

Accessing settings, customizing unit names, and checking firmware.

App Operating Modes and Temperature Settings

App Special Functions Overview

App Unit Controls: Display Light, Energy Saving, Freeze Guard

App Sleep Mode Settings

App Timer Mode Scheduling

App Timer Setup: Days and Times

App Timer Configuration Details

App Area Fan Setting Configuration

AC Pro AWH12QC-D3DNA3D/I Specifications

General IconGeneral
BrandAC Pro
ModelAWH12QC-D3DNA3D/I
CategoryAir Conditioner
LanguageEnglish