Questions and Answers

  • J
    Joanna DudleyJul 31, 2025
    How to troubleshoot AC Pro AWHD(30)ND3G/O Air Conditioner that won't start?
    • M
      Matthew YoungJul 31, 2025
      If your AC Pro Air Conditioner isn't starting, first, ensure there isn't a power outage. If power is available, inspect the power supply circuit and confirm the power plug is securely connected. Also, verify the wiring between the indoor and outdoor units is correct per the circuit diagram and that all wiring terminals are firmly connected. Check if the air conditioner is reliably grounded and the wiring is correct. Inspect the power cord for damage and replace if needed. Ensure the air switch is appropriate for the unit. Finally, try replacing the remote controller batteries or repairing/replacing the controller.
  • B
    Brandon PayneAug 5, 2025
    Why is my AC Pro AWHD(30)ND3G/O not cooling or heating properly?
    • P
      Pamela VelasquezAug 5, 2025
      If your AC Pro Air Conditioner isn't cooling (or heating) well, start by adjusting the set temperature. Increase the fan speed of the indoor unit to medium or high. Clean the indoor unit's filter. Ensure proper installation positions for both indoor and outdoor units, including rain and sun protection for the outdoor unit. If refrigerant is leaking, identify and fix the leak, then add more refrigerant. If these steps don't resolve the issue, there may be a malfunction of 4-way valve or capillary. Also make sure that the flow volume of valve is sufficient. For malfunctions of horizontal louver, the IDU fan motor, the ODU fan motor, or the compressor, consult the corresponding maintenance instructions.
  • J
    John YatesAug 9, 2025
    What to do if the compressor on my AC Pro AWHD(30)ND3G/O Air Conditioner won't operate?
    • B
      benderbenjaminAug 9, 2025
      If your AC Pro Air Conditioner compressor isn't operating, ensure the wiring is correctly connected and all terminals are secure, following the wiring diagram. Replace the compressor capacitor if it's damaged. If the power voltage is too low or high, consider installing a voltage regulator. If the compressor coil is burnt out or the cylinder is blocked, the compressor may need repair or replacement.
  • C
    Crystal WeaverAug 13, 2025
    How to fix the horizontal louver on my AC Pro AWHD(30)ND3G/O Air Conditioner when it doesn't swing?
    • A
      Angelica PrinceAug 14, 2025
      If the horizontal louver on your AC Pro Air Conditioner isn't swinging, check the wire connections according to the wiring diagram to ensure they are correct and firmly connected. If the wiring is correct, the stepping motor may be damaged and require repair or replacement. If the issue persists, the main board might be damaged and need replacement with the same model.
  • G
    Gregory ScottAug 17, 2025
    What causes the ODU fan motor on my AC Pro AWHD(30)ND3G/O to stop working?
    • G
      garciawilliamAug 18, 2025
      If the ODU fan motor on your AC Pro Air Conditioner isn't operating, first check the wire connections to ensure they are correct and firmly connected, referring to the wiring diagram. If the wiring is correct, the fan's capacitor may be damaged and need replacing. If the power voltage is too low or high, consider installing a voltage regulator. If the motor is damaged, change the compressor oil and refrigerant; if this doesn't help, replace the compressor.
  • S
    Stephen WintersAug 21, 2025
    What to do if my AC Pro Air Conditioner is leaking water?
    • W
      woodsanthonyAug 21, 2025
      If your AC Pro Air Conditioner is leaking, clear any blockages in the drain pipe to ensure proper water flow. If the drain pipe is broken, replace it. If the wrapping is loose, re-wrap and bundle it tightly to prevent further leaks.
  • R
    Robert BakerAug 27, 2025
    Why does my AC Pro AWHD(30)ND3G/O make abnormal sounds and vibrations?
    • L
      lauren46Aug 27, 2025
      Normal operation of the AC Pro Air Conditioner can produce sounds as the unit turns on or off due to panel expansion or refrigerant flow; these sounds should diminish quickly. If there are foreign objects inside the indoor or outdoor unit, remove them. Adjust the position of all parts inside the unit, tighten screws, and apply damping plaster between connected parts. If there is a short circuit inside the magnetic coil, replace it. If the compressor shakes abnormally, adjust the support foot mat and tighten the bolts. If there's an unusual sound inside the compressor, and too much refrigerant was added during maintenance, reduce the refrigerant level. For other compressor issues, replace the compressor.

Summary

1. SAFETY PRECAUTIONS

2.1 PREPARATION BEFORE INSTALLATION

2.1.2 Selecting installation site

Provides guidelines for choosing a safe and suitable installation location, considering weather and accessibility.

2.1.3 Piping Connection

2.2 Installation Instruction

2.2.2 Installation of the Connection Pipe

2) Allowable pipe length and drop height among indoor and outdoor units

2.3 Air Purging and Refrigerant Charge

2.2.4 Electric Wiring

3. TROUBLESHOOTING

3.1 MALFUNCTION INDICATOR

Lists various malfunctions, their indicator display codes (lights and indoor display), and meanings.

3.2 MALFUNCTION CHECKING & ELIMINATION

Malfunction display: E6 Communication malfunction

Provides a flowchart for diagnosing and resolving E6 communication malfunctions between indoor and outdoor units.

Malfunction display: E1 Compressor High Pressure Protection

Malfunction display: E4 Compressor Exhaust High Temperature Protection

Malfunction display: E5 Compressor Overheat

Malfunction display: F2 Failure of Evaporator Temp. Sensor

Malfunction display: F3 Failure of Outdoor Ambient Sensor

Malfunction display: F5 Failure of Exhaust Temp. Sensor

3.3 TROUBLESHOOTING FOR NORMAL MALFUNCTION

5. REMOVAL PROCEDURE

REFRIGERANT SYSTEM DIAGRAM

ELECTRICAL PART WIRING DIAGRAM

AC Pro AWHD(30)ND3G/O Specifications

General IconGeneral
BrandAC Pro
ModelAWHD(30)ND3G/O
CategoryAir Conditioner
LanguageEnglish