4
decal is installed on the machine to serve as a reminder of
basic safety practice. It should be read before attempting
to use the brake lathe.
2. Special Precautions: This ACCU-Turn brake lathe was designed
to machine the portions of the brake drum, disc brake rotor
and flywheel surfaces that come in contact with the friction
material. When used according to the instructions herein,
this lathe will perform satisfactorily within the workpiece
size range designated for this model.
During the machining operation, the workpiece rotates. Be
especially cautious of rotating wheel lugs, spokes and
mounted accessories. During machining, material removal may
cause a sharp edge to be generated, where a chamfer or radius
previously existed. Use care in handling machined parts.
3. Securing the Machine: The model 8944 weighs approximately 470
pounds and must be bolted to an ACCU-TURN Heavy duty Floor
Stand or a bench capable of supporting the machine, its
accessories and workpiece.
4. Grounding the Machine: In the event of a malfunction or
breakdown, grounding provides a path of least resistance for
electric current to reduce the risk of electric shock. The
lathe is equipped with an electric cord having an equipment-
grounding conductor and a grounding plug. The plug must be
plugged into a matching outlet that is properly installed and
grounded in accordance with all local codes and ordinances.
Do not modify the plug provided. If the plug will not fit the
outlet, have the proper outlet installed by a qualified
electrician.
Improper connection of the equipment-grounding conductor can
result in a risk of electric shock. The conductor with
insulation having an outer surface that is green with or
without yellow stripes is the equipment-grounding conductor.
If repair or replacement of the electric cord or plug is
necessary, do not connect the equipment-grounding conductor to
a live terminal.
Check with a qualified electrician or service personal if the
grounding instructions are not completely understood, or if in
doubt as to whether the lathe is properly grounded.