AccuAir AS7812 - Specifications; Important Safety Information

AccuAir AS7812
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2
Important Safety Information
Input:
Voltage: 18-30 VAC
Output:
Maximum: 1 amp per terminal (3 amp total for all terminals)
Temperature control ranges: 45°F to 90°F Accuracy: ± 1°F
Differential range: 1°F to 3°F
System configurations: Single-stage heat, single-stage cool
or single-stage heat pump, gas, oil,
electric
Terminations: R, W, Y, O, B, G, C
SET
ROOM
DIFF
Temperature
differential setting
Room temperature
Room temperature
setpoint
Always turn off the thermostat before installing, removing, cleaning, or servicing; turn off the power at
the main power source by unscrewing fuse or switching off circuit breaker
Do not switch to “Cool” if room temperature is below 50
°
F; this could damage your A/C system and
cause injury
Do not install on voltages higher that 30 VAC
All wiring must conform to local and national building and electrical codes and ordinances
While cleaning, do not get soap directly on thermostat switches or LCD readout; only use a damp cloth
with a mild soap to wipe outside of thermostat cover
Specications