EasyManua.ls Logo

AccuBANKER LED430 - 3.2 Watermark Verification Operation; 3.3 Magnetic Verification Operation (only for LED430 model)

AccuBANKER LED430
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
8
3.2 Watermark Verication Operation
Press the WM function button to turn the WM screen ON, the entire inspection area will
be illuminated to make bill’s analysis procedure easier and faster. Proceed to verify the
watermark features embedded in the bill or document and conrm their authenticity. The
absence, displacement, or low quality of this feature will indicate the bill is not genuine.
The internal timer will keep the WM ON for about 50 sec., in case you require more time,
just press the WM button again.
3.3 Magnetic Verication Operation (only for LED430 model)
Once the detector is turned ON, the magnetic circuitry is already active and remains so
while the unit is ON.
Proceed to rub the area of the bill that must contain magnetic ink against the magnetic
head. If the verication window ash in GREEN color and at the same time a BEEPING
sound is emitted, it conrms the Magnetic ink feature is present on the area just veried.
In case none of these signs are present, means there is not MG ink in the scanned area.
3. Operation Description