User Manual The S-TAD 3-3
Programming Mode
While in programming mode, the Enter button’s
LED winks quickly. In addition, the Enter button
LED will also indicate if a programming step
was completed successfully.
If the Enter button LED flashes green slowly the
operation completed correctly. 3 flashes on the
first entry, 5 flashes on the verify entry.
If the Enter button LED flashes red or yellow, an
entry error has occurred. If an entry error occurs,
press the Power/Clear button to cancel out and
start over.
To enter programming mode:
1. Press: Enter, Enter, Master Code, Enter,
Enter
Note: 198237645 is the default master
code.
2. While in programming mode, the Enter
button’s green LED winks quickly.
To exit programming mode:
1. Press: Power/Clear
2. Press: 0, Enter, 0, Enter
Programming mode exits and the Enter
button LED extinguishes.
Set Unlock Timeout:
1. Enter Programming Mode
2. Press: 5, Enter, 5, Enter
(3 slow green flashes)
3. Press: 1 through 5 for 1 to 5 minute
timeout
(5 slow green flashes confirms
4. Exit Programming Mode
To change the master code:
1. Enter Programming Mode
2. Press: 1, Enter, 1, Enter
(3 slow green flashes)
3. Press: The current 9-digit master code to
change, then Enter
(1 slow green flash if correct)
4. Press: New 9-digit master code, then
Enter
(1 slow green flash if correct)
5. Press: Same new 9-digit master code to
verify, then Enter
(5 slow green flashes confirms)
6. Exit Programming Mode