- 13 -
Test Specification:
1. Frequency Hertz 5 ~
250 HZ , PSD Level
0.0054 (G2/Hz)
2. Grms = 1.146
3. Sweep Time : 30
minutes per Axis
4. Axes : X,Y,Z
Unpackaged, Non-
Operating
Test Spectrum:
20 Hz 0.0185(g2/Hz)
200Hz 0.0185(g2/Hz)
Duration : 5 Minutes
Axis : 3 axis ( Horizontal
and Vertical axis ,Z axis)
76 cm Height (MP stage)
(1 corner, 3 edges, 6 faces)
Wooden package, Non-
Operating
1. Amplitude : Half sine-wave
50G
2. Duration : 10 ms
3. Test Times : 1
4.Test Sides : All 6 Sides
3.3.6 Electrostatic Discharge Requirements
3.3.7 EMC
Band 1 < 10 V/m
Band 2 < 1 V/m
Band 1 < 200nT
Band 2 < 25nT
After Mass production
under 1dBuv for constant
measure. Besides DNSF
and VCCI class-2 are
optional.
3.3.8 Reliability
Note-4: CCFL lifetime is determined as the time at which brightness of lamp is 50%. The typical lifetime of