ACME ENGINEERING &
MANUFACTURING CORP.
P.O. Box 978
Muskogee, Oklahoma 74402
AcmeFan.com
Form 610427
This set of instructions applies to both the direct driven and belt driven fans with WSS slant housing and the WSSC
slant collar. CAUTION: Model ADR36G8 should not be operated with a timer.
Remove from shipping crate prior to installation. All debris and shipping material must be removed to prevent obstruction of
air ow to and from the orice. The orice opening on both sides must be kept clear of obstructions. Failure to keep the orice
opening clear could cause undue stresses on the propeller blades, damage to the fan, and an unsafe operating condition.
INSTALLATION & MAINTENANCE INSTRUCTIONS
BREEZEMASTER MODEL BDR/ADR W/WSS & WSSC
3
4
5
6
10
11
12
15
16
2
19
20
9
26
1
13
14
17
2221
23
7
8
18
25
24
Power Cable Path
BDR COMPONENTS
CODE DESCRIPTION QTY.
1 Roll Pin 1
2 Propeller 1
3 5/16 Whiz Lock Nut 20
4 Orice 1
5 Support Angle 2
6 5/16 X 3/4 Bolt 24
7 Bearing Base 2
8 Bearing 2
9 Shaft 1
10
Fan Sheave (with or without
housing)
1
11 Motor Base 1
12 Rubber Ring 2
13 Motor 1
14 Motor Sheave 1
15 Belt 1
16 Belt Tightener 1
17 Belt Tightener Bracket 1
18 1/4 x 3/4 Bolt 2
19 1/4 Whiz Lock Nut 2
20 Key 8mm x 8mm 1
21 3/8 Lock Washer 1
22 3/8 x 1 1/4 bolt 1
23 Cable Clips 3
24 Large Water Plug 2
25 Small Water Plug 2
26 Water Shield 2
SIZE
N
IN mm
BDR/ADR36 45.13 1146
BDR48 59.45 1510
BDR48J2 62.38 1584
BDR54 67.00 1702
WARNING! Do not use fans in hazardous environments where the fan’s electrical system could provide ignition to combustible
or ammable materials, unless built specically for that environment. This unit has rotating parts and safety precautions
should be exercised during installation, operation and maintenance.
Minimum Fan Center to Center Spacing Cone Fans
Note: This minimum distance will
place the fans in a side by side
position with the cones touching.