Page #1 background imageLoading...
Page #1 background image
CEILING VENTILATOR
MODELVQ080ESa VQ110ES
VQ090ESa VQ150ES
VQ120ES
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR IN -
JURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock the service disconnecting means to prevent
power from being switched on accidentally. When the ser-
vice disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done by a
qualied person(s) in accordance with all applicable codes
and standards, including re-rated construction codes and
standards.
4. Sufcient air is needed for proper combustion and exhausting
of gases through the ue (chimney) of fuel burning
equipment to prevent backdrafting. Follow the heating
equipment manufacturer’s guideline and safety standards
such as those published by the National Fire Protection
Association (NFPA), and the American Society for Heating,
Refrigeration and Air Conditioning Engineers (ASHRAE), and
the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Acceptable for use over a tub or shower when connected to
a GFCI (Ground Fault Circuit Interrupter) - protected branch
circuit (ceiling installation only).
8. This unit must be grounded.
9. Never place a switch where it can be reached from a tub or
shower.
10. To reduce the risk of fire use only metal ductwork.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
2. This product is designed for installation in ceilings up to a
12/12 pitch (45 degree angle). Duct connector must point up.
DO NOT MOUNT THIS PRODUCT IN A WALL.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Please read specication label on product for further
information and requirements.
CLEANING & MAINTENANCE
For quiet and efcient operation, long life, and attractive
appearance - lower or remove grille and vacuum interior of unit
with the dusting brush attachment.
The motor is permanently lubricated and never needs oiling. If the
motor bearings are making excessive or unusual noises, replace
the motor with the exact service motor. The impeller should also
be replaced.
OPERATION
Use an on/off switch to operate this fan. See “Connect Wiring
for details.
WARRANTY
LIMITED WARRANTY Acme Engineering and Manufacturing Corporation extends
this limited warranty to the original purchaser and warrants that products described
herein shall be free from original defects in workmanship and materials for two
years from date of shipment provided same have been properly handled, stored,
installed, serviced, maintained and operated. THIS WARRANTY DOES NOT
EXTEND TO FLUORESCENT LAMP STARTERS AND TUBES.
Refer to Form
MS149 for complete limited warranty terms and conditions. This form is available
to anyone at www.acmefan.com. The Company's warranty is in lieu of all other
warranties, express or implied, arising by law or otherwise, including without
limitation the implied warranties of merchantability and fitness for a particular
purpose, which are hereby expressly disclaimed claimed and waived.
Acme products are designed and manufactured to provide reliable performance but
they are not guaranteed to be 100% free of defects. Even reliable products will
experience occasional failures and this possibility should be recognized by the
Purchaser and End User. If these products are used in a life support ventilation
system where failure could result in loss or injury, the Purchaser and End User
should provide adequate back-up ventilation, supplementary natural ventilation or
failure alarm system, or acknowledge willingness to accept the risk of such loss or
injury.
WARNING DO NOT use in HAZARDOUS ENVIRONMENTS where fans electrical
system could provide ignition to combustible or flammable materials unless unit is
specifically built for hazardous environments. Comply with all local and national
safety codes including the National Electrical Code (NEC) and National Fire
Protection Act (NFPA). Guards must be installed when fan is within reach of
personnel or within eight (8) feet (2.5 m) of working level or when deemed
advisable for safety.
DISCLAIMER The Company has made a diligent effort to illustrate and describe
the products in this literature accurately; however, such illustrations and
descriptions are for the sole purpose of identification, and do not express or imply a
warranty that the products are merchantable, or fit for a particular purpose.
INDEMNITY Purchaser acknowledges various warnings by the Company
regarding the products and its installation and use. If the Company incurs any
claims, lawsuits, settlements, or expenses (including attorney fees) for any loss,
injury, death or property damage including, but not limited to, claims arising out of
the Purchasers or any end users installation or use of the products, the Purchaser
shall indemnify and hold the Company harmless.
Acme Engineering and Manufacturing Corporation
1820 N. York St., Muskogee, OK 74403
918-682-7791
Installer: Leave this manual with the owner.
Form611130
Question and Answer IconNeed help?

Do you have a question about the ACME VQ080ESa and is the answer not in the manual?

ACME VQ080ESa Specifications

General IconGeneral
BrandACME
ModelVQ080ESa
CategoryFan
LanguageEnglish

Summary

READ AND SAVE THESE INSTRUCTIONS

General Safety Warnings

Provides critical warnings to reduce fire, electric shock, or injury risks during installation and use.

General Cautionary Notes

Highlights cautions for general ventilation use, installation pitch, and preventing motor damage from dust.

CLEANING & MAINTENANCE

OPERATION

WARRANTY AND DISCLAIMER

TYPICAL INSTALLATIONS

PLAN THE INSTALLATION

INSTALL HOUSING

Mounting to Joist or I-joist

Mount housing to joist or I-joist using screws or nails through mounting flanges.

Mounting Between Framing

Mount housing between framing using provided hanger bars, spanning up to 24 inches.

INSTALL DUCTWORK

Attach Damper/Duct Connector

Snap the damper/duct connector onto the housing, ensuring it locks and the flap closes.

Install 6" Round Ductwork

Connect 6" round ductwork to the fan connector and vent it to the outside.

CONNECT WIRING

Electrical Connection Procedure

Connect electrical wiring according to local codes and NEC, using UL approved connectors.

INSTALL GRILLE

Grille Attachment

Insert grille springs into housing slots and push grille against ceiling.

USE AND CARE

Safety Precautions for Servicing

Disconnect power supply and lock out service panel before cleaning or servicing the unit.

Cleaning Instructions

Clean plastic parts with mild soapy water and a soft cloth; avoid abrasive materials.

Fan Assembly Cleaning

Gently vacuum fan, motor, and housing interior; never immerse electrical parts in water.