When lighting up, the lamp operates at high pressure and there is a slight risk of arc tube
rupture. The risk increases with age, temperature and improper handling of the lamp. Do
not use the lamp longer than its lifespan.
Make sure the lamp is located in the center of the reflector for the best projection
5.3 Change The Lamp
Do not use this lamp more than 3000 hours, Using the lamp any longer than its set life could
seriously damage your unit. Periodically checking the lamp running time, when the lamp reaches
the 3000 hour mark, or close to it, we strongly suggest you switch the lamp out. Clear the RESET
TIME after you have replaced the lamp.
1. Remove the fixture head covers using a screwdriver (Figure 1).
Figure 1
2. Lift the lamp out of its recess, disconnect the lamp and connect a new lamp that must be the
same type with the old one. And then place the new lamp into the lamp recess.