EasyManua.ls Logo

ACONLABS ON CALL EXPRESS User Manual

ACONLABS ON CALL EXPRESS
108 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
i
Blood Glucose Monitoring System
Self monitoring of blood glucose (SMBG) is an important part of diabetes care, but
the high cost of testing can make it difficult. At ACON, our goal is to provide high
quality glucose monitoring systems at a price that allows you to test as often as
necessary. Together, we can better manage your diabetes and help you live a
longer and healthier life.
Welcome, and thank you for choosing the On Call
®
Express Blood Glucose
Monitoring System. The On Call
®
Express Blood Glucose Monitoring System will
give you accurate blood glucose results in just a few simple steps.
The On Call
®
Express Blood Glucose Monitoring System uses an electrochemical
enzymatic assay. It is for the quantitative detection of glucose in fresh capillary
whole blood. It allows people with diabetes to take blood samples from the fingertip,
forearm or palm. It is used at home as a way to monitor the effectiveness of
diabetes control programs. Alternative testing sites (forearm and palm) should be
used only during steady-state times (when blood glucose level is not changing
rapidly). The On Call
®
Express Blood Glucose Monitoring System is intended to be
used by a single patient and should not be shared. Alternative Site Testing (AST)
should not be used to calibrate continuous glucose monitors (CGMs) nor for use in
insulin dose calculations. On Call
®
Express Blood Glucose Monitoring System is
for single patient use only. Do not share with others.
To ensure accurate results from your On Call
®
Express Blood Glucose Monitoring
System, please follow these guidelines:
Read instructions before use.
Use only On Call
®
Express Blood Glucose Test Strips with the On Call
®
Express
Blood Glucose Meter.
For in vitro diagnostic use only. Your blood glucose monitoring system is to be
used only outside the body. It’s for monitoring the effectiveness of diabetes
control. It should not be used for the diagnosis of diabetes.

Table of Contents

Questions and Answers:

ACONLABS ON CALL EXPRESS Specifications

General IconGeneral
Test Time4 seconds
Operating Humidity10 - 90% RH
Hematocrit Range30 - 55%
Blood SampleCapillary whole blood
Measurement Range20-600 mg/dL
Sample Size0.4 µL
Battery TypeCR2032
Battery Life1000 tests
Operating Temperature5 to 45°C
Storage Conditions32-86°F (0-30°C), 10-90% RH

Summary

Getting Started

Component Descriptions

Lists and explains each component included with the blood glucose monitoring system.

Installing the Battery

Meter Setup Before Testing

Testing Your Blood

Getting a Drop of Blood

Instructions on how to prepare and obtain a blood sample for testing using the lancing device.

Testing Blood Glucose

Detailed procedure for performing a blood glucose test using the meter and test strips.

Using the Meter Memory

Performing a Quality Control Test

Maintenance

Replacing the Battery

Procedures for replacing the meter's battery when it is low or depleted.

Caring for Your On Call® Express Blood Glucose Monitoring System

Guidelines for cleaning and disinfecting the blood glucose meter and lancing device.

Suggested Testing Times and Target Goals

Comparing Meter and Laboratory Results

Troubleshooting Guide

Specifications

Warranty