4: Installation
-
2030-004A
Connecting the
Water
To ensure
proper operation
of
Machine
the
following
requirements
must
be mLet:
'
Cold water
source
with
a
shutoff
valve
and female
%" NPT fitting.
.
Minimum
of 30psi.
.
Maximum
100psi
.
Water source
must
be
located
within
5 feet of
machine.
.
All machines
are installed
with
a 2000
grain
water treatment
system
.
If location
has
a reverse
osmoses
system, a
freshwater bypass
is required.
Gonnecting the
Water
Treatment
System
All machines
axe installed
with
a
2000 Grain
water treatment
system. Wall
space
must be available
and
located
within
5
feet of machine.
'
Dimensions:
25"Hx
11"Wx5.25"D
'
Mount the
system
as close
as
possible to the machine.
.
Flush the
cartridge
for
5 minutes
prior
to connecting
to machine.
Everpure6
2000
Grain
Water
Treatment
System
@l
'-Jn
lruw
I Ll
r:_l
rT--l.pm
u
water
flow
input
water flow output
Problems with Reverse
Osmosis
Water System
A fresh water bypass
is required
for sites with
a Reverse Osmoses
Filter
System.
Machine water
level sensors
are inoperative
when used
with this system.
Gonnecting Electrical
The minimum electrical
requirements
must be met to ensure
proper
operation of
machine:
.
200-240
vAC,50l60Hz
.
30 amp dedicated
circuit
.
NEMA
LI4-30
receptacle,
a four
wire circuit with a neutral leg. U.S.
machines are typically
wired
for single-phase operation.
.
200-240VAC
Three-Phase
and High
Leg
are available.
4-6
Acorto 2000sii Technical
Support