This document describes the Upright Hot Oil Temperature Control Units, models TCO-U and 2016U. These units are designed for precise temperature control in various industrial applications, particularly those requiring hot oil circulation.
The Upright Hot Oil Temperature Control Unit is a single-pass heater tank system designed to maintain optimal balance of fluid velocity versus watt density, and turbulence for excellent heat transfer, with minimal pressure drop. The high fluid velocity significantly prolongs the life of the heater and fluid. It operates as an easy-to-operate microprocessor-based PID control device, where the process reaches the set point, and PID control cycles the cooling valve and/or immersion heater to maintain the proper leaving water temperature. The controller is factory tested and set to the desired process temperature set point, controlling the rest of the unit's operations.
The unit features a pump and immersion heaters to circulate and heat the thermal fluid. A cooling valve is included for temperature regulation. The system incorporates various safety features, including a pressure switch, safety thermostat, and reservoir tank. The electrical control system is designed for reliability, safety, and simplicity of operation, with clear labeling of switches and status indicators.
The units are designed for three-phase voltage operation. The nominal supply voltage is 460/3/60 (Verify on serial number tag). The allowable voltage fluctuation is +/- 10%, and allowable frequency fluctuation is continuous +/- 1%. The maximum operating temperature is 550°F (288°C), with a minimum operating temperature of 0°F (-18°C). The reservoir capacity is 7 gallons (26.5 liters).
Key electrical features include non-fused lockable rotary disconnect, branch circuit fusing, and NEMA 12 electrical enclosure. The unit can be supplied with 6, 12, 18, or 24 kW low density immersion heaters, depending upon the heating needs of the process. The 18 and 24 kW models are built to provide full or partial heat as required by the process and determined by the controller, to provide more precise control.
The pump is a mechanical, positive displacement pump, featuring a nearly maintenance-free design and excellent heat transfer capabilities. It is well suited for use with a variety of commercially available heat transfer fluids. The pump is capable of running in either direction. The pump reverse feature can be used to draw fluids back from the process.
The unit's ambient operating conditions are 40 degrees Celsius – Maximum (104 degrees Fahrenheit), with 50% relative humidity. It is designed for sea level altitude and clean, dust-free, non-explosive environments. The unit is equipped with minimal, i.e., machine mounting vibration.
The unit is designed for ease of use with a microprocessor-based PID control device. The control panel includes a START button to initiate the pump, a STOP button to halt the pump, and a REVERSE button for pump reversal. A VENT button is used to purge air and water from the unit and process. The MODE SELECT switch allows selection between AUTO or Maintained (manual cooling) positions. An ALARM SILENCE button is present to mute audible alarms.
The system includes various indicators for operational status:
The unit is designed for easy installation, with clear instructions for uncrating, rigging, and electrical and piping connections. It is crucial to follow safety warnings regarding high voltage, hot surfaces, pinch points, and lock-out/tag-out procedures during installation and operation.
Routine maintenance is crucial for optimal performance and longevity. A maintenance schedule is provided, detailing weekly, monthly, quarterly, and every six months checks.
Weekly:
Monthly:
Quarterly:
Every Six Months:
Preventative Maintenance:
Corrective Maintenance:
Troubleshooting tables are provided to diagnose common problems such as temperature fluctuations, units not heating or achieving set point, and rapid pressure drops. These tables list possible causes and corrective actions.