CEILING CONCEALED
SPLIT TYPE AIR CONDITIONER
(C Series)
Model: IM-CCC-0501-ACSON
CEILING
CONCEALED
INSTALLATION MANUAL

Table of Contents

Questions and Answers

  • T
    Tracy SmithAug 8, 2025
    What to do if my Acson international A5LC50CR Air Conditioner unit does not operate?
    • I
      Isabel AndersonAug 8, 2025
      If your Acson international air conditioner unit isn't operating, there are several possible causes: * There may be a power failure, or the fuse might need replacement. Check the power supply and replace the fuse if necessary. * The power plug could be disconnected. Ensure it is properly reconnected. * The delay timer may be set incorrectly. Verify and adjust the delay timer settings.
  • B
    Bryan JohnsonAug 13, 2025
    How to fix a dim remote control display for Acson international A5LC50CR?
    • M
      Michael RhodesAug 13, 2025
      If the remote control display for your Acson international air conditioner is dim: * The batteries may be flat. Replace them. * The batteries may be incorrectly placed. Reinsert them correctly.
  • K
    Kristen WilsonAug 18, 2025
    How to increase airflow in my Acson international Air Conditioner?
    • S
      Susan BryantAug 18, 2025
      If the airflow from your Acson international air conditioner is too low, consider the following: * The air filter might be dirty. Clean or replace it. * Open doors or windows can affect airflow. Close them. * The air suction and discharge may be clogged. Clear any obstructions. * The regulated temperature may be set too low. Increase it.
  • B
    Bruce Martinez PhDAug 23, 2025
    Why does my Acson international A5LC50CR Air Conditioner have a bad odor?
    • C
      Christopher Hall DDSAug 23, 2025
      A bad odor from your Acson international air conditioner can be caused by particles like cigarette smoke or perfume that have adhered to the coil. Cleaning the coil may remove the odors.
  • J
    James LawsonAug 28, 2025
    Why is there condensation on my Acson international Air Conditioner?
    • V
      Veronica HesterAug 28, 2025
      Condensation on the front air grille of your Acson international air conditioner's indoor unit can occur due to air humidity after prolonged operation. To address this: * Reduce humidity in the room. * If the set temperature is too low, increase the temperature setting and operate the unit at high fan speed.
  • R
    Ronald BaileySep 2, 2025
    Why does my Acson international Air Conditioner make a hissing sound?
    • M
      moralesannaSep 2, 2025
      A hissing sound from your Acson international air conditioner during operation may be due to refrigerant fluid flowing into the evaporator coil. Check the refrigerant levels.

Summary

Safety Precautions

General Safety Warnings

Crucial safety warnings for installation and maintenance personnel to prevent hazards and ensure safe operation.

Installation Site Warnings

Important cautions regarding installation locations, such as avoiding laundry rooms or areas with flammable gas.

Installation Diagram and Indoor Unit Installation

Indoor Unit Installation Guidelines

Instructions for installing the indoor unit, including mounting and clearance requirements.

Outdoor Unit Installation and Refrigerant Piping

Refrigerant Piping Works

Electrical Connection

Refrigerant Handling Precautions

R410 A Refrigerant Precautions

Specific safety and installation guidelines for systems using R410A refrigerant, including tool requirements.

R407 C Refrigerant Precautions

Guidelines for handling R407C refrigerant, emphasizing POE oil and filter-dryer installation.

Purging the Refrigerant Piping

Additional Refrigerant Charge

Refrigerant Leak Check and Compressor Charging

Copeland Scroll Compressor Charging

Precautions and procedures for charging units with Copeland Scroll compressors, focusing on vacuum and lubrication.

Troubleshooting Guide

Common Faults and Causes

Identifies common operational faults, their potential causes, and basic troubleshooting steps.

Acson international A5LC50CR Specifications