A4MSD SERIES COOLING ONLY(50HZ)+A6
MODEL INDOOR UNIT
OUTDOOR UNIT AWMS10F AWMS10F AWMS10F AWMS15F AWMS15F AWMS15F
NOMINAL kcal/h 2,268 3,024
COOLING W 2,638 3,517
CAPACITY Btu/h 9,000 12,000
ONE UNIT RUNNING W 1,035 1,035 1,035 1,566 1,566 1,566
TWO UNITS RUNNING W
ONE UNIT RUNNING A 4.40 4.40 4.40 7.00 7.00 7.00
TWO UNITS RUNNING A
POWER SOURCE V/Ph/Hz
REFRIGERANT / CONTROL
FAN TYPE
HIGH CFM/LPS 300 / 141.6 300 / 141.6
MEDIUM CFM/LPS 230 / 108.6 270 / 127.4
LOW CFM/LPS 190 /89.7 230 / 108.6
FAN MOTOR
RATED INPUT POWER W 25 30
RATED RUNNING CURRENT A 0.11 0.13
FAN MOTOR PROTECTION
MATERIAL
DIAMETER mm/in
THICKNESS mm/in
MATERIAL
THICKNESS mm/in
ROW
FIN PER INCH
FACE AREA
m
2
/
ft
2
HEIGHT mm/in
DIMENSION WIDTH mm/in
DEPTH mm/in
WEIGHT kg
SOUND PRESSURE LEVEL ( H/M/L ) dBA 38 / 34 / 30 38 / 35 / 31
ROOM TEMPERATURE
CONTROL AIR DISCHARGE
OPERATION
CONDENSATE DRAIN SIZE mm/in 16 / 0.63
AIR FILTER
PACKING HEIGHT mm/in
DIMENSION WIDTH mm/in
DEPTH mm/in
COMPRESSOR TYPE
NUMBER
CAPACITOR µF
LOCK ROTOR AMP A
PROTECTION DEVICE
POWER SOURCE V/Ph/Hz
FAN TYPE / DRIVE
BLADE MATERIAL
DIAMETER mm/in
RATED RUNNING CURRENT A
RATED OUTPUT POWER W
RATED INPUT POWER W
MATERIAL
DIAMETER mm/in
THICKNESS mm/in
MATERIAL ALUMINIUM (SLIT FIN TYPE)
THICKNESS mm/in
ROW
FIN PER INCH
FACE AREA m
2
/ft
2
HEIGHT mm/in
WIDTH mm/in
DEPTH mm/in
kg
SOUND PRESSURE LEVEL dBA
MATERIAL GALVANISED MILD STEEL
THICKNESS mm/in
FINISHING
TYPE
SIZE LIQUID mm/in
GAS mm/in
PACKING HEIGHT mm/in
DIMENSION WIDTH mm/in
DEPTH mm/in
kg 0.750 0.800
1) ALL SPECIFICATIONS ARE SUBJECTED TO CHANGE BY THE MANUFACTURER WITHOUT PRIOR NOTICE.
2) ALL UNITS ARE BEING TESTED AND COMPLY TO ARI 210/240-94
3) NOMINAL COOLING AND HEATING CAPACITY ARE BASED ON THE CONDITIONS BELOW:
a) COOLING - 26.7°C DB / 19.4°C WB INDOOR AND 35°C DB OUTDOOR
4) SOUND PRESSURE LEVEL IS ACCORDING TO JIS B 8615 STANDARD.
POSITION OF THE MEASUREMENT POINT IS 1.0 m IN FRONT AND 1.0 m BELOW THE UNIT.
5) ALL SPECIFICATIONS ARE TENTATIVE SPECIFICATIONS AT THE TIME OF PRINTING. PLEASE CONSULT YOUR DEALER FOR CONFIRMATION.
4 POLES X 12W
8.08 10.70
13.28
4 POLES X 10W
R407C / OUTDOOR CAPILLARY TUBE
300 / 141.6
270 / 127.4
230 / 108.6
300 / 141.6
230 / 108.6
190 /89.7
RATED POWER
CONSUMPTION
RATED RUNNING
CURRENT
INDOOR UNIT
AIR FLOW
COIL
TUBE
FAN
A4MSD1010A A4MSD1015A A4MSD1515A
2,268 3,024
2,638 3,517
9,000 12,000
1,900 2,431 2,962
REFRIGERANT CHARGE 2 x 0.750 2 x 0.800
FAN
DIMENSION
ANTI FUNGUS CROSS FLOW TANGENTIAL FAN / DIRECT
220 ~ 240 / 1 / 50
SEAMLESS INNER GROOVED COPPER
7.0 / 0.276
0.28 / 0.011
FIN
ALUMINIUM (HYDROPHILIC SLIT FIN)
0.11 / 0.0043
2
18
0.193 / 2.08
290 / 11.4
815 / 32.1
179 / 7.0
9.5
38 / 34 / 30
371 / 14.6
875 / 34.4
38 / 35 / 31
MICROCOMPUTER CONTROLLED THERMOSTAT
AUTOMATIC LOUVER (UP & DOWN) & MANUAL ADJUST GRILLE (LEFT & RIGHT)
LCD WIRELESS MICRO COMPUTER REMOTE CONTROL
WASHABLE SARANET
269 / 10.6
COMP
OVERLOAD PROTECTION
220 ~ 240 / 1 / 50
ROTARY
2
3220
30
COIL
TUBEFIN
9.52 / 3/8
0.33 / 0.013
0.12 / 0.005
16
0.51 / 5.53
2
WEIGHT
63 64
CASING
PIPE
FLARE VALVE
6.35 / 1/4
9.52 / 3/8
6.35 / 1/4
12.7 / 1/2
461 / 18.1
840 / 33.1
330 / 13
62
54
0.8 / 0.031
EPOXY-POLYESTER POWDER
710 / 28.0
982 / 38.7
170
SEAMLESS INNER GROOVED COPPER
PROPELLER/DIRECT
GLASS REINFORCED ACRLY STYRENE RESIN
OUTDOOR UNIT
BUILT IN THERMAL FUSE
25 30
0.11 0.13
406.4 / 16
0.72
646 / 25.4
80
15

Related product manuals