Loading...
Wall Mounted Split Systems
AWM - J - 2010
AWM09J/JR
AWM15J/JR
AWM20J/JR
AWM25J/JR
A5WM10J/JR
A5WM15J/JR
Models:

Questions and Answers

  • C
    collinschristineJul 25, 2025
    Why is the airflow too slow or the room not cooling enough with my Acson AWM15J?
    • M
      Michael GutierrezJul 25, 2025
      If your Acson Air Conditioner isn't cooling well or the airflow is weak, several factors could be at play. First, a dirty air filter can restrict airflow, so try cleaning it. Ensure that all windows and doors are properly closed. Also, check that neither the air suction nor the discharge vents on the indoor and outdoor units are blocked. If they are, repair any clogging or replace faulty components. Finally, verify that the temperature setting isn't too high; try using a lower temperature setting.
  • J
    James MortonJul 30, 2025
    Why does the compressor in my Acson AWM15J Air Conditioner keep running continuously?
    • J
      John WalkerJul 30, 2025
      If the compressor in your Acson Air Conditioner runs non-stop, there are a few things to check. Make sure the air filter is clean because a dirty filter can cause this issue. Also, the temperature setting might be too low if you're cooling, so try increasing it. Conversely, if you're heating, the temperature setting might be too high, so try decreasing it.
  • J
    Jennifer LangAug 2, 2025
    How to fix a dim wireless controller display on my Acson AWM15J?
    • T
      tserranoAug 2, 2025
      If the display on your Acson Air Conditioner's wireless controller is dim, the batteries are likely the issue. Try replacing them. If that doesn't work, make sure the batteries are inserted correctly. Also, check the assembly of the controller.
  • K
    Kristin PetersonAug 7, 2025
    Why is there condensation on the air grille of my Acson Air Conditioner?
    • M
      Michael HendersonAug 7, 2025
      Condensation on the front grille of your Acson Air Conditioner's indoor unit is usually due to air humidity after prolonged use. To resolve this, increase the temperature setting and run the unit at a high fan speed.
  • T
    Tyler ThompsonAug 11, 2025
    Why does my Acson Air Conditioner have a bad odor coming from it?
    • S
      Steven HoldenAug 11, 2025
      If the airflow from your Acson Air Conditioner smells bad, it could be due to particles like cigarette smoke or perfume that have stuck to the coil. In this case, contact your nearest dealer.
  • L
    Lori MorganAug 16, 2025
    Why doesn't the compressor start right away on my Acson AWM15J Air Conditioner?
    • A
      ashley35Aug 16, 2025
      If the compressor in your Acson Air Conditioner doesn't start immediately after turning the unit on, this is likely due to a built-in protection against frequent starting. Allow 3 to 4 minutes for the compressor to start on its own.
  • R
    Rita WhiteAug 20, 2025
    Why is my Acson AWM15J not blowing warm air during heating?
    • J
      Jennifer CallahanAug 20, 2025
      If your Acson Air Conditioner isn't blowing warm air during the heating cycle, it might be in defrost mode. The heating operation will resume automatically after the defrost cycle is complete.

Summary

Nomenclature and Product Overview

Model Nomenclature

Explains the structure of indoor and outdoor unit model names.

Product Line-Up Details

Details available models and their features across different series.

Unit Features and Operation

Key Unit Features

Describes advanced features like air filtration and self-diagnosis.

Controller Operation Guide

Explains the functions and operation of the remote controller.

Installation and Safety

Operating Range and Guidelines

Specifies operating temperature limits and critical installation advice.

Piping and Electrical Work

Details refrigerant piping, connections, and electrical wiring requirements.

Refrigerant Handling Precautions

Specific safety guidelines for R410A refrigerant.

Technical Data and Performance

Sound Data

Presents noise level measurements and NC curves for various models.

Engineering & Physical Data

Provides detailed electrical and physical specifications for units.

Performance Data Tables

Outlines cooling and heating capacities under various conditions.

Electrical, Wiring, and Troubleshooting

Electrical Data

Lists electrical ratings and specifications for unit components.

Wiring Diagrams

Shows electrical schematics for cooling and heat pump units.

Troubleshooting Guide

Identifies common faults, causes, and corrective actions.

Maintenance and Parts Information

Service and Maintenance Procedures

Routine checks and cleaning for unit longevity.

Exploded View and Part List

Visual breakdown of unit components for repair and identification.

Acson AWM15J Specifications

General IconGeneral
TypeSplit Air Conditioner
RefrigerantR410A
Power Supply220-240V, 50Hz
Energy Efficiency Ratio (EER)11.0 BTU/W-hr
EER (Energy Efficiency Ratio)11.0 BTU/W-hr
Operating Temperature (Cooling)18°C to 43°C