Installation Guide
11
Step 2: Do the Wiring
Determine the devices that you will connect to the reader/controller.
1. The reader/controller comes with terminal blocks to easily connect devices to the unit. Once
you determine the devices to connect, cut off the needed terminal blocks and connect to the
corresponding terminal cable wires. Below is an example of connecting the wires to the
supplied terminal block.
TIP: For the most basic operation, the terminal cables for Ethernet, CN4 (for power adapter
and lock relay, etc.), CN5 (for wiegand connections) are commonly used.
2. Route the cables such as the power source and other devices (such as door lock, sensor,
etc.) that will be connected to the reader/controller through the hole on the wall and the
mounting plate.
3. Then connect the devices to the supplied terminal block. Below is an example of connecting
a DC 12V power adapter. Note that the RED wire connects to the DC 12V wire of the power
adapter (cable with white lines) while the BLACK wire connects to the ground wire of the
power adapter.
4. Continue to connect other devices, as needed. Refer to Wiring Diagram on page 13.
White stripe: Connects to 12V Pin
Connects to GND Pin