General Safety Information
1. Always carefully read, thoroughly understand and follow the pump operating instructions. Use this pump correctly and with
care for the purpose for which it is intended. Failure to do so may cause damage or personal injury, and will void the
warranty. Please retain instructions for future reference.
2. Contact your chemical or fluid supplier to check for compatibility with pump prior to installation and operation.
3. Prior to use, always carefully and thoroughly read and understand the OSHA information contained in the MSDS sheet
supplied for the chemical which is to be pumped.
4. Wear protective clothing (goggles, face mask, long sleeves, long pants, gloves, aprons, etc) as set forth in the OSHA
Safety Data Sheet when pumping any hazardous chemicals.
5. When using flammable liquids, pump containers should be grounded to avoid static electricity.
6. Any pump used for transferring flammable liquids must be stored in a ventilated area after use.
7. Pump should be washed out before it is used since processing lubricants may contaminate the fluids.
8. Prior to use, inspect your pump thoroughly verifying its proper assembly.
9. If pump is removed from drum, it should be thoroughly rinsed in a liquid that is compatible with the pump.
Operating Instructions & Parts Manual for Model P490
This pump is designed to fit 15, 30 & 55 gallon drums with 2" and 1-1/2" female threaded openings.
The pump is adjustable to pump 8, 10 or 12 oz per stroke. The pump is commonly used for pumping certain Alcohols,
lubricants, detergents.
Specifications
Flow rate per stroke. . . . . . . . . . . . . . . . . . . . . . . . . 8, 10, or 12 oz
Inlet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1"
Outlet. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7/8"
Bung Adapter. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2" & 1-1/2" NPT
Suction Tube (Length & Material). . . . . . . . . . . . . . .36" PP
Packing Gland. . . . . . . . . . . . . . . . . . . . . . . . . . . . . Viton
Wetted Parts. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PP, Steel & Viton
Viscosity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1000 cps
Max. Temp. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140°F
Revised 04/01/2004
1. Check to see if all parts are present.
Installation
nut.
pump leaks at the top replace packing
Normal maintenance is not required. If
Maintenance
leakage.
Tighten only enough to preventNOTE:
Exploded parts view on reverse side
2. Attach part#17 (tube) to bottom
of part#1 (pump body).
3. Attach part#18 (telescoping tube)
4. Insert part#7 (screws) into part#6
(handle lever) & part#8 (handle)
then tighten of part#7 (nuts) to
each screw.
5. Slip part#2 (coupling nut) threaded end
first over part#3 (spout) and insert
part#3 (spout) into part#1
(pump body) then tighten
part#2 (coupling nut)
You may adjust the flow rate by
moving part#7 into the different holes
of part#8. The hole on part#8 that
is farthest away from part#6 will
pump at a rate of 12 oz per stroke.
the center hole will pump at a rate of
10 oz per stroke and the 3rd hole
will pump at a rate of 8 oz per stroke.
Question and Answer IconNeed help?

Do you have a question about the Action P490 and is the answer not in the manual?

Summary

General Safety Information

Safety Precautions

Always read, follow, and understand all safety instructions and warnings provided in the manual before operating the pump.

Exploded Parts Diagram

Installation

Step-by-step guide for assembling the pump components, including attaching the spout, handle, and telescoping tubes.

Maintenance

Information regarding pump maintenance, noting that routine maintenance is not required unless leaks are observed.

Parts List

Overview

This document describes the P490 pump, an adjustable pump designed for dispensing liquids from drums.

Function Description:

The P490 pump is designed to fit 15, 30, and 55-gallon drums that have 2-inch and 1-1/2-inch female threaded openings. Its primary function is to pump liquids, with an adjustable flow rate of 8, 10, or 12 ounces per stroke. The pump is commonly used for dispensing alcohols, lubricants, and detergents.

Important Technical Specifications:

  • Flow rate per stroke: Adjustable to 8, 10, or 12 ounces.
  • Bung Adapter: Compatible with 2-inch and 1-1/2-inch NPT (National Pipe Taper) threaded openings.
  • Inlet: 1 inch.
  • Outlet: 7/8 inch.
  • Suction Tube (Length & Material): 36 inches, made of PP (Polypropylene).
  • Packing Gland: Viton.
  • Wetted Parts: Constructed from PP, Steel, and Viton, ensuring compatibility with a range of chemicals.
  • Viscosity: Capable of handling liquids up to 1000 cps (centipoise).
  • Max. Temp.: Can operate in temperatures up to 140°F.

Usage Features:

  • Adjustable Flow Rate: The pump's flow rate can be adjusted by moving part #7 (nut & screw) into different holes on part #8 (handle). The hole farthest from part #6 (handle lever) yields 12 oz per stroke, the center hole yields 10 oz per stroke, and the third hole yields 8 oz per stroke.
  • Compatibility Check: Users are advised to contact their chemical or fluid supplier to verify compatibility with the pump before installation and operation.
  • Safety Precautions:
    • Always read, understand, and follow operating instructions carefully.
    • Review OSHA information in the MSDS sheet for the chemical being pumped.
    • Wear appropriate protective clothing (goggles, face mask, long sleeves, long pants, gloves, aprons, etc.) as specified by OSHA when handling hazardous chemicals.
    • When pumping flammable liquids, pump containers should be grounded to prevent static electricity.
    • Pumps used for flammable liquids must be stored in a ventilated area after use.
    • The pump should be washed out before its initial use, as processing lubricants may contaminate fluids.
    • Thoroughly inspect the pump for proper assembly before use.
    • If the pump is removed from a drum, it should be thoroughly rinsed with a compatible liquid.
  • Installation Steps:
    1. Verify all parts are present.
    2. Attach part #17 (tube) to the bottom of part #1 (pump body).
    3. Attach part #18 (telescoping tube).
    4. Insert part #7 (screws) into part #6 (handle lever) and part #8 (handle), then tighten part #7 (nuts) to each screw.
    5. Slip part #2 (coupling nut) threaded end first over part #3 (spout).
    6. Insert part #3 (spout) into part #1 (pump body).
    7. Tighten part #2 (coupling nut).
    • Note: Tighten only enough to prevent leakage.

Maintenance Features:

  • Normal Maintenance: The manual states that normal maintenance is not required.
  • Leakage Resolution: If the pump leaks at the top, the packing nut should be replaced.
  • Cleaning: The pump should be washed out before initial use and rinsed with a compatible liquid if removed from a drum.

Action P490 Specifications