Art. Nr.: 13690 Pelletfackel Apollo
Seite 20 von 21
The use of the appliance as an incinerator or in any case the use in a different
way for which it was built is prohibited.
It is forbidden to use other types of fuel for powering or switching on the appli-
ance.
The use of any pellet other than that indicated is prohibited. The use of fuel that
does not comply with the above specifications, in addition to immediately void-
ing the appliance warranty, can create dangerous situations.
Preliminary Check up
All preliminary checks must be performed at the first ignition or after a long
period of inactivity.
Check that the positioning of the appliance respects the safety distances.
Check that there are no flammable materials near the appliance. For safety distances
see Paragraph 18
In case of an ignition after a long period of inactivity, all parts of the brazier, the glass
and the fan area, must have previously been inspected and cleaned of ash and dust.
Check that there are no flammable materials inside the combustion chamber (docu-
mentation, cables, paper, etc.)
22. Start
After unpacking the appliance, prepare all accessories nearby.
Before starting the ignition phase it is advisable to carry out preliminary checks:
• Check that the positioning of the appliance respects the safety distances.
• Check that the appliance has no obstructions on the top near the smoke outlet.
• Check that the appliance is positioned flat, stable and perfectly vertical
Once the device is turned on, the pellet load must be completely burned according to
the cycle and the process must not be interrupted.
NOTE
During the first ignition, the appliance will exhale, for a few hours, the smell of paint.
Recall that these odors are annoying but are not harmful.
After each operating cycle, it is normal for a minimum residual amount of ash to remain
in the tank, which must be removed before starting the next cycle.