Note:Iftheinflowandoutflowfittingsareofdifferentsizes,typicallythelargeroneisused
ontheinflowandthesmalleroneontheoutflow.
4. Attachthedesiredlengthoftubingontoeachinflowandoutflowfittingadapterwith
thewormdrivehoseclamps.Theinflowshouldconnectthechillertotheappropriate
sizedsubmersiblewaterpump,suchasanActiveAqua,inthepropersizedreservoir
(see attached performance chart).Theoutflowtubeshouldhangfreelyinthereservoir
toreintroducethechilledwaterbackintotheholdingtank.
Operation:
1. DoNOTpoweronthechillerunityet.Fullysub m ergethewaterpumptobeused,plugit
in,andensurethatwaterismovingfreelybetweentheholdingreservoirandthechiller
unit.
2. Plugthechillerintoagroundedoutletandensurethepowerswitchlocatedontheback
oftheunitisinthe“ON”(I)position.
SettingtheTemperature:
1. PressandholdtheSETbutton downforapproximately3secondstoenterthewater
temperatureprogrammingmode.Thepreviouswatertemperaturesettingwilldisplay.
2. Usethe/\or\/buttonsonthecontrolpaneltoincreaseordecreasethedesiredwater
temperature.PresstheSETbuttononcemore,orwaitapproximately8secondsto
selectthedesiredtemperature.
TemperatureDisplay:
• PresstheSETbuttononcetodisplaythecurrentsettemperaturevalueofthechiller
unit; pressitagaintodisplaytheactualtemperaturevalueofthewater.Theblinking
displayindicatesthesettemperature.
TemperatureErrorAdjustment:
1. Whenthereservoirwatertemperaturediffersfromthesettemperaturevalue,an“II”
indicationshouldappearinthedisplay.