EasyManua.ls Logo

ACV Prestige 24 Solo - User Manual

ACV Prestige 24 Solo
107 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
A1004308 - 660Y2900- Volume 0 • B
EN
FR
NL
ES
IT
DE
PL
RU
THE INSTALLERS HANDBOOK FOR HEATING SYSTEMS
CONTROLLED WITH ACVMAX
Prestige 24 - 32 Solo /Excellence
Prestige 42 - 50 - 75 - 100 - 120 Solo
HeatMaster 25 C
HeatMaster 25 - 35 - 45 - 70 - 85 - 120 TC
WaterMaster 25 - 35 - 45 - 70 - 85 - 120
VOLUME 0
Introduction
Applicable to appliances manufactured from March 2016, equipped with at least software version (DSP) 3.05

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the ACV Prestige 24 Solo and is the answer not in the manual?

Summary

Recommendations

Important Instructions - Read Before Proceeding

Provides critical safety and operational guidelines before installation or use.

Applicability

Specifies the appliances and software versions this manual applies to.

Important Instructions - Read Before Proceeding

Essential Recommendations for Safety

Details critical safety precautions for installation and operation.

Users Guide

How to Use This Manual

Explains the structure and navigation of the installer handbook.

ACVMax Description and Operation

ACVMax Operating Information

Overview of the ACVMax system's capabilities and features.

Control Panel Description

Details the components and functions of the ACVMax control panel.

Home Page Description

Explains the information displayed on the ACVMax home screen.

Appliance Easy Setup (EZ Setup)

Guides through the simplified setup process for immediate appliance operation.

Selecting the Language

Instructions on how to change the language displayed on the ACVMax controller.

Installer Code

Explains how to access installer-specific settings using a code.

Installer Menu Structure

Diagram illustrating the navigation path within the installer menu.

Installer Menu Description

Details the functions and icons available in the installer menu.

CH Settings

Configuration settings for Central Heating (CH) operation.

Demand Type Screen Menu

Explains the options for generating Central Heating (CH) demand.

CH Maximum Capacity

Sets the maximum capacity for Central Heating (CH) output.

Absolute CH Setpoint

Limits the Central Heating (CH) setpoint to ensure safe operating temperatures.

CH1 Max. Setpoint

Defines the maximum setpoint for CH1 heating calls.

CH1 Min. Setpoint

Defines the minimum setpoint for CH1 heating calls.

CH2 Circuit

Enables or disables the CH2 heating circuit.

CH2 Maximum Setpoint

Sets the maximum setpoint for CH2 heating calls.

CH2 Minimum Setpoint

Sets the minimum setpoint for CH2 heating calls.

Warm Weather Shutdown

Configures an outdoor temperature to disable Central Heating (CH) function.

Circulation Pump Permanent

Allows central heating circulators to be constantly enabled.

CH Post Pump Time

Sets how long heating circulators continue to operate after a heating call.

Freeze Protection

Enables or disables the frost protection mechanism.

Frost Protection Setpoint

Defines the outdoor temperature threshold for anti-freeze activation.

Parallel Shift

Allows external adjustment of CH setpoint with Constant demand type.

CH Call Blocking

Sets minimum time between burner firings for central heating calls.

DHW Setting

Configuration settings for Domestic Hot Water (DHW) operation.

DHW Operation

Enables or disables the domestic hot water function.

DHW Boiler Setpoint

Sets the fixed appliance temperature for DHW calls with Thermostat demand.

DHW Setpoint

Sets the storage setpoint temperature for DHW calls with Sensor demand.

DHW On Differential

Defines how far DHW storage temp. must fall to create a DHW call.

DHW Storage Adder

Computes the appliance setpoint for DHW calls with Sensor demand.

DHW Post Pump Time

Sets how long the DHW circulator operates after a DHW call.

DHW Priority Timeout

Sets a time limit for DHW calls having priority over central heating.

DHW Priority

Enables or disables the domestic hot water priority function.

DHW Call Blocking

Sets minimum time between burner firings for domestic hot water calls.

DHW To CH Call Blocking

Sets minimum time between DHW and CH burner firings.

Antilegionella Function

Ensures indirect water heater is heated weekly to prevent Legionella.

Boiler Settings

Configuration settings related to appliance operation.

Lockout Temp.

Sets the overheat thermostat function for testing.

Modbus Address

Sets the Modbus address for communication.

Pump Settings

Allows selection of pump configuration for the hydraulic setup.

Flexible Pump Config

Customizes pump configuration for specific hydraulic needs.

Ignition Level

Adjusts the fan start speed for appliance ignition.

Mix zone high limit

Limits the maximum temperature in the mixed circuit.

Appliance Setting

Allows changing appliance type/model using specific codes.

Reset All Settings

Resets all CH, DHW, and Cascade settings to default values.

Cascade Menu

Navigates to cascade system related menus.

Manual Operation

Allows manual testing of the burner and circulators.

ACVMax Parameters for the Specialist

List of Status Line Messages

Provides descriptions for status messages displayed on the ACVMax screen.

Appliance Codes

Lists codes for changing appliance type and model.

Factory Settings and Reset Values

Details the default settings and reset values for various parameters.

ACVMax Menu Structure

Diagram showing the hierarchical structure of the ACVMax menus.

Users Guide

General

Provides an overview of the volume's content and appliance compatibility.

Resistance of the Temperature Sensors

Lists resistance values for temperature sensors at different temperatures.

Prestige Solo;Excel (3-Way Valve)

Electrical Characteristics Prestige 24-32 Solo;Excellence

Details electrical specifications for Prestige 24-32 Solo/Excellence models.

Pumps (Prestige Solo;Excel (3-Way valve))

Explains pump configurations for Prestige Solo/Excel (3-way valve).

Preset Configuration 1

Details the wiring and settings for Preset Configuration 1.

Preset Configuration 2

Details the wiring and settings for Preset Configuration 2.

Preset Configuration 3

Details the wiring and settings for Preset Configuration 3.

Preset Configuration 4

Details the wiring and settings for Preset Configuration 4.

Prestige Solo (2 Pumps)

Electrical Characteristics Prestige 42 - 50 - 75 Solo

Details electrical specifications for Prestige 42-50-75 Solo models.

Electrical Characteristics Prestige 100-120 Solo

Details electrical specifications for Prestige 100-120 Solo models.

Pumps (Prestige Solo)

Explains the pump configurations available for Prestige Solo models.

Preset Configuration 1

Details wiring and settings for Preset Configuration 1 for Prestige Solo.

Preset Configuration 4

Details wiring and settings for Preset Configuration 4 for Prestige Solo.

Preset Configuration 8

Details wiring and settings for Preset Configuration 8 for Prestige Solo.

Preset Configuration 3

Details wiring and settings for Preset Configuration 3 for Prestige Solo.

Preset Configuration 10

Details wiring and settings for Preset Configuration 10 for Prestige Solo.

Preset Configuration 7

Details wiring and settings for Preset Configuration 7 for Prestige Solo.

Preset Configuration 2

Details wiring and settings for Preset Configuration 2 for Prestige Solo.

Preset Configuration 9

Indicates Preset Configuration 9 is not activated and should not be used.

Preset Configuration 12

Details wiring and settings for Preset Configuration 12 for Prestige Solo.

Heatmaster and Watermaster

Electrical Characteristics HeatMaster 25-35-45 TC, HeatMaster 25 C and WaterMaster 25 - 35 - 45

Provides electrical specifications for HeatMaster and WaterMaster 25-45 models.

Electrical Characteristics of HeatMaster 70-85 TC, WaterMaster 70 - 85

Details electrical specifications for HeatMaster and WaterMaster 70-85 models.

Electrical Characteristics of HeatMaster 120 TC, WaterMaster 120

Details electrical specifications for HeatMaster and WaterMaster 120 models.

Pumps (Heatmaster)

Explains pump configurations for HeatMaster appliances.

Pumps (Watermaster)

Describes available pump configurations for WaterMaster appliances.

Heatmaster

Preset Configuration 16

Details wiring and settings for Preset Configuration 16 for HeatMaster.

Preset Configuration 15

Details wiring and settings for Preset Configuration 15 for HeatMaster.

General Information

Users Guide

Provides an overview of cascade systems and their setup.

Operating Principles of an ACVMax-Controlled Cascade

Explains how ACVMax controls multiple boilers in a cascade system.

Menus and Screens Description

Cascade Menu -> Cascade Information

Displays real-time operating information for the Cascade System.

Cascade Menu -> Cascade Settings

Contains adjustable settings for cascade operation.

Maximum Firing Rate

Sets the maximum firing capacity of a single boiler in the cascade.

CH; DHW Boilers

Specifies how many boilers respond to DHW calls in a split cascade.

Auto Rotation

Equalizes burning hours among appliances for balanced wear.

CH Proportional Gain

Adjusts cascade response for central heating calls based on temperature deviation.

CH Integral Gain

Adjusts cascade response for central heating calls near the setpoint.

DHW Proportional Gain

Adjusts cascade response for DHW calls based on temperature deviation.

DHW Integral Gain

Adjusts cascade response for DHW calls near the setpoint.

Cascade -> Cascade Autodetection

Automatically detects and configures all boilers in the cascade system.

Structure of the ACVMax Cascade Menu

Provides a visual overview of the cascade menu hierarchy.

Installation of the Cascade Boilers

General Process for Cascade Installation

Step-by-step guide for installing cascade boilers.

Installation and Configuration of Cascade Systems

Assembling the Cascade Mounting Rack

Instructions for assembling the mounting rack for cascade boilers.

Hydraulic Connections of Cascade Systems

Details the hydraulic connections required for cascade systems.

Chimney Connections of Cascade Systems

Provides guidance on connecting chimneys for cascade systems.

Cascade System Connection (4-Boiler Cascade)

Explains the electrical connections for a 4-boiler cascade system.

Cascade Start-up Process

Steps for starting up the cascade system after installation.

Accessing the Cascade Autodetection Page

Guides on how to access and initiate cascade autodetection.

Preset Configuration 2

Details wiring and settings for a 3-boiler cascade configuration.

Preset Configuration 5

Details wiring and settings for a 3-boiler cascade configuration.

Chimney Connections

Chimney Connection Characteristics for Prestige Boilers

Describes various flue pipe connection types for Prestige boilers.

Calculation of Flue Pipe System - Prestige Appliances

Provides methods and tables for calculating flue pipe lengths for Prestige appliances.

Prestige Solo Cascade: Maximum Length of Flue Pipes

Specifies maximum flue pipe lengths for Prestige Solo cascades.

Chimney Connection Characteristics for Heatmaster and Watermaster Appliances

Details flue pipe connection types for Heatmaster and Watermaster appliances.

Calculation of Flue Pipe System - Heatmaster and Watermaster Appliances

Provides methods for calculating flue pipe lengths for Heatmaster/Watermaster appliances.

Cascade: Calculation of the Maximum Length of Flue Pipes

Specifies maximum flue pipe lengths for Heatmaster/Watermaster cascades.

Volume 5 - Troubleshooting

Blockage and Error Codes

Lists error codes, fault descriptions, and solutions for troubleshooting.

Summary

Recommendations

Important Instructions - Read Before Proceeding

Provides critical safety and operational guidelines before installation or use.

Applicability

Specifies the appliances and software versions this manual applies to.

Important Instructions - Read Before Proceeding

Essential Recommendations for Safety

Details critical safety precautions for installation and operation.

Users Guide

How to Use This Manual

Explains the structure and navigation of the installer handbook.

ACVMax Description and Operation

ACVMax Operating Information

Overview of the ACVMax system's capabilities and features.

Control Panel Description

Details the components and functions of the ACVMax control panel.

Home Page Description

Explains the information displayed on the ACVMax home screen.

Appliance Easy Setup (EZ Setup)

Guides through the simplified setup process for immediate appliance operation.

Selecting the Language

Instructions on how to change the language displayed on the ACVMax controller.

Installer Code

Explains how to access installer-specific settings using a code.

Installer Menu Structure

Diagram illustrating the navigation path within the installer menu.

Installer Menu Description

Details the functions and icons available in the installer menu.

CH Settings

Configuration settings for Central Heating (CH) operation.

Demand Type Screen Menu

Explains the options for generating Central Heating (CH) demand.

CH Maximum Capacity

Sets the maximum capacity for Central Heating (CH) output.

Absolute CH Setpoint

Limits the Central Heating (CH) setpoint to ensure safe operating temperatures.

CH1 Max. Setpoint

Defines the maximum setpoint for CH1 heating calls.

CH1 Min. Setpoint

Defines the minimum setpoint for CH1 heating calls.

CH2 Circuit

Enables or disables the CH2 heating circuit.

CH2 Maximum Setpoint

Sets the maximum setpoint for CH2 heating calls.

CH2 Minimum Setpoint

Sets the minimum setpoint for CH2 heating calls.

Warm Weather Shutdown

Configures an outdoor temperature to disable Central Heating (CH) function.

Circulation Pump Permanent

Allows central heating circulators to be constantly enabled.

CH Post Pump Time

Sets how long heating circulators continue to operate after a heating call.

Freeze Protection

Enables or disables the frost protection mechanism.

Frost Protection Setpoint

Defines the outdoor temperature threshold for anti-freeze activation.

Parallel Shift

Allows external adjustment of CH setpoint with Constant demand type.

CH Call Blocking

Sets minimum time between burner firings for central heating calls.

DHW Setting

Configuration settings for Domestic Hot Water (DHW) operation.

DHW Operation

Enables or disables the domestic hot water function.

DHW Boiler Setpoint

Sets the fixed appliance temperature for DHW calls with Thermostat demand.

DHW Setpoint

Sets the storage setpoint temperature for DHW calls with Sensor demand.

DHW On Differential

Defines how far DHW storage temp. must fall to create a DHW call.

DHW Storage Adder

Computes the appliance setpoint for DHW calls with Sensor demand.

DHW Post Pump Time

Sets how long the DHW circulator operates after a DHW call.

DHW Priority Timeout

Sets a time limit for DHW calls having priority over central heating.

DHW Priority

Enables or disables the domestic hot water priority function.

DHW Call Blocking

Sets minimum time between burner firings for domestic hot water calls.

DHW To CH Call Blocking

Sets minimum time between DHW and CH burner firings.

Antilegionella Function

Ensures indirect water heater is heated weekly to prevent Legionella.

Boiler Settings

Configuration settings related to appliance operation.

Lockout Temp.

Sets the overheat thermostat function for testing.

Modbus Address

Sets the Modbus address for communication.

Pump Settings

Allows selection of pump configuration for the hydraulic setup.

Flexible Pump Config

Customizes pump configuration for specific hydraulic needs.

Ignition Level

Adjusts the fan start speed for appliance ignition.

Mix zone high limit

Limits the maximum temperature in the mixed circuit.

Appliance Setting

Allows changing appliance type/model using specific codes.

Reset All Settings

Resets all CH, DHW, and Cascade settings to default values.

Cascade Menu

Navigates to cascade system related menus.

Manual Operation

Allows manual testing of the burner and circulators.

ACVMax Parameters for the Specialist

List of Status Line Messages

Provides descriptions for status messages displayed on the ACVMax screen.

Appliance Codes

Lists codes for changing appliance type and model.

Factory Settings and Reset Values

Details the default settings and reset values for various parameters.

ACVMax Menu Structure

Diagram showing the hierarchical structure of the ACVMax menus.

Users Guide

General

Provides an overview of the volume's content and appliance compatibility.

Resistance of the Temperature Sensors

Lists resistance values for temperature sensors at different temperatures.

Prestige Solo;Excel (3-Way Valve)

Electrical Characteristics Prestige 24-32 Solo;Excellence

Details electrical specifications for Prestige 24-32 Solo/Excellence models.

Pumps (Prestige Solo;Excel (3-Way valve))

Explains pump configurations for Prestige Solo/Excel (3-way valve).

Preset Configuration 1

Details the wiring and settings for Preset Configuration 1.

Preset Configuration 2

Details the wiring and settings for Preset Configuration 2.

Preset Configuration 3

Details the wiring and settings for Preset Configuration 3.

Preset Configuration 4

Details the wiring and settings for Preset Configuration 4.

Prestige Solo (2 Pumps)

Electrical Characteristics Prestige 42 - 50 - 75 Solo

Details electrical specifications for Prestige 42-50-75 Solo models.

Electrical Characteristics Prestige 100-120 Solo

Details electrical specifications for Prestige 100-120 Solo models.

Pumps (Prestige Solo)

Explains the pump configurations available for Prestige Solo models.

Preset Configuration 1

Details wiring and settings for Preset Configuration 1 for Prestige Solo.

Preset Configuration 4

Details wiring and settings for Preset Configuration 4 for Prestige Solo.

Preset Configuration 8

Details wiring and settings for Preset Configuration 8 for Prestige Solo.

Preset Configuration 3

Details wiring and settings for Preset Configuration 3 for Prestige Solo.

Preset Configuration 10

Details wiring and settings for Preset Configuration 10 for Prestige Solo.

Preset Configuration 7

Details wiring and settings for Preset Configuration 7 for Prestige Solo.

Preset Configuration 2

Details wiring and settings for Preset Configuration 2 for Prestige Solo.

Preset Configuration 9

Indicates Preset Configuration 9 is not activated and should not be used.

Preset Configuration 12

Details wiring and settings for Preset Configuration 12 for Prestige Solo.

Heatmaster and Watermaster

Electrical Characteristics HeatMaster 25-35-45 TC, HeatMaster 25 C and WaterMaster 25 - 35 - 45

Provides electrical specifications for HeatMaster and WaterMaster 25-45 models.

Electrical Characteristics of HeatMaster 70-85 TC, WaterMaster 70 - 85

Details electrical specifications for HeatMaster and WaterMaster 70-85 models.

Electrical Characteristics of HeatMaster 120 TC, WaterMaster 120

Details electrical specifications for HeatMaster and WaterMaster 120 models.

Pumps (Heatmaster)

Explains pump configurations for HeatMaster appliances.

Pumps (Watermaster)

Describes available pump configurations for WaterMaster appliances.

Heatmaster

Preset Configuration 16

Details wiring and settings for Preset Configuration 16 for HeatMaster.

Preset Configuration 15

Details wiring and settings for Preset Configuration 15 for HeatMaster.

General Information

Users Guide

Provides an overview of cascade systems and their setup.

Operating Principles of an ACVMax-Controlled Cascade

Explains how ACVMax controls multiple boilers in a cascade system.

Menus and Screens Description

Cascade Menu -> Cascade Information

Displays real-time operating information for the Cascade System.

Cascade Menu -> Cascade Settings

Contains adjustable settings for cascade operation.

Maximum Firing Rate

Sets the maximum firing capacity of a single boiler in the cascade.

CH; DHW Boilers

Specifies how many boilers respond to DHW calls in a split cascade.

Auto Rotation

Equalizes burning hours among appliances for balanced wear.

CH Proportional Gain

Adjusts cascade response for central heating calls based on temperature deviation.

CH Integral Gain

Adjusts cascade response for central heating calls near the setpoint.

DHW Proportional Gain

Adjusts cascade response for DHW calls based on temperature deviation.

DHW Integral Gain

Adjusts cascade response for DHW calls near the setpoint.

Cascade -> Cascade Autodetection

Automatically detects and configures all boilers in the cascade system.

Structure of the ACVMax Cascade Menu

Provides a visual overview of the cascade menu hierarchy.

Installation of the Cascade Boilers

General Process for Cascade Installation

Step-by-step guide for installing cascade boilers.

Installation and Configuration of Cascade Systems

Assembling the Cascade Mounting Rack

Instructions for assembling the mounting rack for cascade boilers.

Hydraulic Connections of Cascade Systems

Details the hydraulic connections required for cascade systems.

Chimney Connections of Cascade Systems

Provides guidance on connecting chimneys for cascade systems.

Cascade System Connection (4-Boiler Cascade)

Explains the electrical connections for a 4-boiler cascade system.

Cascade Start-up Process

Steps for starting up the cascade system after installation.

Accessing the Cascade Autodetection Page

Guides on how to access and initiate cascade autodetection.

Preset Configuration 2

Details wiring and settings for a 3-boiler cascade configuration.

Preset Configuration 5

Details wiring and settings for a 3-boiler cascade configuration.

Chimney Connections

Chimney Connection Characteristics for Prestige Boilers

Describes various flue pipe connection types for Prestige boilers.

Calculation of Flue Pipe System - Prestige Appliances

Provides methods and tables for calculating flue pipe lengths for Prestige appliances.

Prestige Solo Cascade: Maximum Length of Flue Pipes

Specifies maximum flue pipe lengths for Prestige Solo cascades.

Chimney Connection Characteristics for Heatmaster and Watermaster Appliances

Details flue pipe connection types for Heatmaster and Watermaster appliances.

Calculation of Flue Pipe System - Heatmaster and Watermaster Appliances

Provides methods for calculating flue pipe lengths for Heatmaster/Watermaster appliances.

Cascade: Calculation of the Maximum Length of Flue Pipes

Specifies maximum flue pipe lengths for Heatmaster/Watermaster cascades.

Volume 5 - Troubleshooting

Blockage and Error Codes

Lists error codes, fault descriptions, and solutions for troubleshooting.

ACV Prestige 24 Solo Specifications

General IconGeneral
BrandACV
ModelPrestige 24 Solo
CategoryHeating System
LanguageEnglish

Related product manuals