Details CE certification compliance for safety and hygiene requirements.
Details ETL certification compliance for safety and FAA regulations.
Covers ADB SAFEGATE's obligations for repair or replacement of defective equipment.
Guarantees against mechanical, electrical, and physical defects for two years.
Alerts to safety hazards and conditions, including hazard icons and warnings.
Defines qualified personnel for safe operation, maintenance, and repair.
General safety instructions for installation and use of ADB SAFEGATE equipment.
Specifies the intended function of the equipment and warns against misuse.
Guidelines for proper storage to prevent damage from weather, condensation, and dust.
Ensures safe operation by qualified personnel, adherence to manuals, and system checks.
Highlights electric shock hazards and procedures for safe maintenance and repair.
Precautions regarding fasteners to prevent Foreign Object Damage (FOD) and ensure proper installation.
Guidelines for handling Electrostatic Sensitive Devices (ESD) to prevent damage.
Instructions on familiarizing with the manual's structure and carrying out actions sequentially.
Defines abbreviations and terms related to Airfield Ground Lighting (AGL).
Lists and defines general abbreviations and terms used in the document.
Introduces the RELIANCE omnidirectional LED fixture and its available versions.
Details specifications, compliance, uses, features, and accessories for LED Apron Maneuvering lights.
Details specifications, compliance, uses, features, and accessories for LED Taxiway Edge lights.
Instructions for unpacking the RELIANCE light fixtures and verifying contents.
Lists the recommended tools for the installation of the light fixture.
Step-by-step instructions for installing and removing the 8-inch light fixture from its base.
Describes the RELIANCE Intelligent Lighting system for control and monitoring.
Explains the RELIANCE IQ system and the 2A concept for switching and monitoring.
Details the SIU for detecting aircraft presence and direction, communicating status signals.
Describes the NCU for concentrating status information from field components.
Explains the SCM as an interface for receiving commands from the NCU.
Details the SCF's role in containing communication signaling within the circuit.
Explains the NCU's role as the main interface for interpreting commands and controlling the system.
Provides instructions for programming the RELIANCE IQ product.
Details the required hardware for RELIANCE IQ programming and setup.
Instructions for connecting a PC to the SCM unit for programming.
Guides on using AMT software for RELIANCE IQ product configuration and programming.
Details on using the ASP Maintenance Tool for configuration and COM port selection.
Further instructions on using the ASP Maintenance Tool for PID and parameter download.
Explains the operational characteristics of connecting RELIANCE IQ in a series circuit.
Describes how IQ is configured to set the lamp state upon circuit energization.
Defines the safe state behavior when communication with SCM is interrupted.
Crucial safety instructions for electrical shock and high light intensity.
Emphasizes understanding system components and referencing relevant standards for safe installation.
Outlines recommended weekly, monthly, and yearly maintenance tasks for the fixture.
Lists tools and general steps for workshop maintenance, including part replacement and checks.
Provides an exploded view and a list of components for the omnidirectional light.
Step-by-step instructions for opening and closing the 8-inch light fixture for maintenance.
Procedure for checking the watertightness of the light fixture using compressed air.
Detailed steps for removing and replacing the light engine in an 8-inch fixture.
Instructions for replacing the LED board holder and tightening screws.
Detailed steps for replacing the LED board, including necessary components and procedures.
Instructions for replacing the top cover of the light fixture.
Instructions for replacing the connection board and connecting cables.
Steps for replacing prisms, gaskets, and blue spacers, emphasizing full component replacement.
Steps for removing and replacing the bottom cover and the converter unit.
Procedures for resetting fail-open converters, including specific models and fuse resistor replacement.
Clarifies the structure of the ordering code for RELIANCE Apron Maneuvering Omni lights.
Clarifies the structure of the ordering code for RELIANCE Taxiway Edge Omni lights.
Lists available components, their article numbers, packing, and screw types with torque specifications.
Details base installation O-ring selection and retaining bolts for 12-inch fixtures.
Provides fixture load, isolation transformer, and CCR load details for RS-AM and RS-TE fixtures.
Explains the formula for calculating cable resistance and loss, with examples.
Information about accessing the ADB SAFEGATE website for product details and resources.
Details on proper disposal and recycling of ADB SAFEGATE products and electronic components.
Provides contact information and addresses for ADB SAFEGATE offices worldwide.
| Brand | ADB Safegate |
|---|---|
| Model | RELIANCE |
| Category | Control Systems |
| Language | English |