103
CAUTION: USE EXTREME CARE WHEN SETTING RETAINING WHEEL TENSION.
PERSONAL INJURY MAY RESULT.
NOTE: Proper retaining wheel tension has been achieved when the wheel spins and stops when slight
pressure is applied (to the retaining wheel itself).
6. Tumbler/Basket Electrical Components
a) Tumbler (Basket) Thermal Magnetic Starter and Auxiliary Contact Block Replacement
1) Discontinue electric service to the dryer.
2) Mark and identify the wires that will be removed for proper reinstallation.
3) Set the control of the thermal magnetic starter to the "stop" position.
4) Press down on the thermal magnetic starter and lift the bottom up and out of the din rail.
5) Mark and identify the wires that will be removed for proper reinstallation.
6) Remove ALL associated wires.
7) Separate the thermal magnetic starter from the auxiliary contact block.
8) Install new thermal magnetic starter or auxiliary contact block.
9) Reassemble the thermal magnetic starter to auxiliary contact block.
10) Set overload to required setting.

Other manuals for ADC AD-310