66
5) Remove the valve support.
6) Remove the two (2) #6-32 x 1" hex head machine bolts by removing the two (2) #6 hex nuts and the
two (2) #6 star washers.
7) To install new air jet assembly, reverse above procedure.
b. Pneumatic Valve Muffler Replacement
1) Disconnect compressed air supply from the dryer.
2) Remove damaged or nonfunctional muffler from valve body.
3) Replace muffler by threading into valve body (snug fit).
4) Reconnect compressed air supply to the dryer.