11
Ref. Part
No. Item# Name Qty.
1 640-01D Chestpiece Drum Assembly 1
2 640-02S Retaining Ring, Ped. 1
3 640-03S Diaphragm, Ped. 1
4 640-15 Zinc Disk, Ped. 1
5 640-14 Zinc Disk, Adult 1
6 640-03 Diaphragm, Adult 1
7 640-02 Retaining Ring, Adult 1
8 641-05T Tubing, 22" (spec. color) 2
9 640-16 Tubing Clip 2
10 640-05 Binaurals with Lg Eartips 1
14 15
17
2
1
3
4
8
6
5
7
9
13
10
11
16
Ref. Part
No. Item# Name Qty.
11 640-07BKN Adsoft Plus Eartips, Large 2
12 640-08BKN Adsoft Plus Eartips, Small 2
13 640-11 Bell, 1 1/4" 1
14 640-12 Bell, 1" 1
15 640-13 Bell, 3/4" 1
16 640-18 Accessory Pouch 1
17 640-19 Chestpiece Key 1
3 640-03S Diaphragm, Ped. (spare) 1
6 640-03 Diaphragm, Adult (spare) 1
- 640-06 Tubing Caps 2
12
To loosen the diaphragm rim, insert the key into the two slots on the threaded portion,
located on the underside of the assembly. While holding the rim steady, turn the key
counterclockwise to loosen the rim.
Remove worn diaphragm and replace it with a new one. Reassemble
the rim and tighten by turning key clockwise until tight. Then re-
assemble diaphragm rim back onto chestpiece drum by turning
clockwise until it is tight.
Orientation of the Headset
To obtain the most comfortable, acoustically sealed aural
fit, rotate each binaural tube approximately 15° forward,
towards the bridge of your nose. Simply twist each tube
where it enters the tubing.
Adjusting the Spring Tension in the Binaurals
To reduce the tension, grip the binaurals firmly using both hands
with fingers at the base of the binaural, thumbs at each side just
before the binaurals meet the tubing. Flex binaural spring
gradually until desired tension is obtained. To increase the
tension, grip the binaurals in the hand and squeeze the
binaural tubes together gradually.
Caution: Excessive adjustment of the spring tension
could weaken the spring.
Replacing Adsoft
TM
Plus Eartips
Slide Adsoft Plus eartip over adapter unit it locks tight
into internal channel. Repeat steps for second aural tube.
Care and Maintenance
• Avoid extreme heat, cold, solvents, or oils.
• Do not leave exposed to direct sunlight for prolonged periods of time.
• Binaurals and tubing can be wiped down with 70% isopropyl alcohol solution or
mild soapy water.
• Eartips may be removed from binaurals for a thorough cleaning.
• Periodically check that eartips are securely affixed to the headset and free from damage.
• Do not immerse stethoscope in any liquid.
• Do not steam sterilize. If sterilization is necessary, gas sterilize only.
Replacement Parts List
Flex
Here
ADC
®
55 Commerce Drive
Hauppauge, NY 11788
U.S.A.
SC Cattus SRL
Str. Baneasa Nr. 10 C
Târgu-Mures, Jud. Mures
România, EU
Inspected in the U.S.A.
Made in China
tel: 631-273-9600
toll free: 1-800-232-2670
fax: 631-273-9659
www.adctoday.com
info@adctoday.com
LIMITED WARRANTY
Please register your stethoscope online at: http://www.adctoday.com/register.
ADC warrants its products against defects in materials and workmanship under normal
use and service as follows:
1. Warranty service extends to the original retail purchaser only and commences
with the date of delivery.
2. Your Adscope
Sprague stethoscope is warranted for five years from date of
purchase (all parts).
What Is Covered: Replacement of parts, and labor.
What Is Not Covered: Transportation charges to and from ADC. Damages caused
by abuse, misuse, accident, or negligence. Incidental, special, or consequential
damages. Some states do not allow the exclusion or limitation of incidental, special,
or consequential damages, so this limitation may not apply to you.
To Obtain Warranty Service: Send item(s) postage paid to ADC, Attn: Repair Dept.,
55 Commerce Dr., Hauppauge, NY 11788. Please include your name and address,
phone no., proof of purchase, and a brief note explaining the problem.
Implied Warranty: Any implied warranty shall be limited in duration to the terms of this
warranty and in no case beyond the original selling price (except where prohibited by law).
This warranty gives you specific legal rights and you may have other rights which vary
from state to state.
For Australian Consumers
Our goods come with guarantees that cannot be excluded under the Australian
Consumer Law. You are entitled to a replacement or refund for a major failure and
compensation for any other reasonably foreseeable loss or damage. You are also
entitled to have the goods repaired or replaced if the goods fail to be of acceptable
quality and the failure does not amount to a major failure.
For our European Customers
A printed copy of this manual can be sent to you at no charge within seven calendar
days. To request a copy, e-mail us at info@adctoday.com.
Our website, https://www.adctoday.com, where these instructions for use are
available fulfills the requirements of personal data protection, according to Directive
95/46/EC and GDPR on the protection of individuals with regard to the processing
of personal data and on the free movement of such data.
Any serious incident that has occurred in relation to this medical device should be
reported to ADC and the competent authority of the Member State in which the user
and/or patient is established.
IB p/n 9330-00 rev 16 (06/13/2023) Printed in the U.S.A.
This manual is available online in a variety of languages,
follow the links for language options:
www.adctoday.com/care
To register your product visit us at:
www.adctoday.com/register
For questions, comments, or suggestions call toll free:
1-800-ADC-2670 or visit: www.adctoday.com/feedback
Correct
Incorrect
Thumbs
Here
9330-00 rev 16.qxp_Layout 1 9/22/23 9:31 AM Page 2