Table 531-1. HLXC Configuration Fields, continued
FIELD TYPE OPTIONS DESCRIPTION DEFAULT
Unit Service State Toggle IS (In-Service) Places the unit in service and allows equipment
alarm reporting by the MPU. Must be set to IS for
reporting of equipment alarms.
OOS
OOS (Out-Of-
Service)
Removes unit from service and stops equipment
alarm reporting by the MPU.
T1 Service State Toggle IS (In-Service) Places facility in service and allows T1 alarm
reporting by the MPU, and enables DS1 PM data
collection.
OOS
OOS (Out-Of-
Service)
Removes facility from service and stops alarm
reporting by the MPU.
User Notes Input Enter up to 30
alphanumeric
characters.
Enter additional information in the space provided. Blank
Note: HLXC Switch and HLXR Switch Setting fields display the switch settings of the module being configured.