ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance
2-182
© 2000, ADC Telecommunications, Inc.
DLP-556
Page 3 of 3
Table 556-1. DS1 Threshold-Crossing Defaults and Range Values
LINE/PATH (NEND) THRESHOLDS
MON TYPE
15-MINUTE
DEFAULT
15-MINUTE
VALID RANGE DAILY DEFAULT
DAILY VALID
RANGE
FCP 5 1 to 5 480 1 to 480
CVL 13340 1 to 16383 133400 1 to 1048575
ESL 65 1 to 900 648 1 to 65535
SESL 10 1 to 63 100 1 to 4095
LOSS 10 1 to 63 100 1 to 4095
CVP 13340 1 to 16383 133400 1 to 1048575
ESP 65 1 to 900 648 1 to 65535
SESP 10 1 to 63 100 1 to 4095
UASP 10 1 to 63 100 1 to 4095
SASP 10 1 to 63 100 1 to 4095
AISSP 10 1 to 63 100 1 to 4095
LINE/PATH (FEND) THRESHOLDS
MON TYPE
15-MINUTE
DEFAULT
15-MINUTE
VALID RANGE DAILY DEFAULT
DAILY VALID
RANGE
FCP-FE 5 1 to 5 480 1 to 480
ESL-FE 65 1 to 63 648 1 to 65535
CVP-FE 13340 1 to 16383 133400 1 to 1048575
ESP-FE 65 1 to 900 100 1 to 65535
SESP-FE 10 1 to 63 100 1 to 4095
UASP-FE 10 1 to 63 100 1 to 4095
CSS-FE 10 1 to 63 100 1 to 4095
SEFSP-FE 10 1 to 63 100 1 to 4095
INTERNAL PARAMETER THRESHOLDS
MON TYPE DEFAULT VALID RANGE
CVs per SESL 1544 1544 to 8000
CVs per SESP 320 320 to 333
CVs per SESP-FE 320 320 to 333
Note: refer to TAP-102 for Mon Type descriptions.