Advanced Central Heating System Flushing
User Guide for Open Vented Systems
Question and Answer IconNeed help?

Do you have a question about the Adey MagnaCleanse and is the answer not in the manual?

Adey MagnaCleanse Specifications

General IconGeneral
BrandAdey
ModelMagnaCleanse
CategoryWater Filtration Systems
LanguageEnglish

Summary

Important Safety Information

Key Safety Warnings

Critical cautions for operating MagnaCleanse RapidFlush filters, including magnet proximity and system heat.

Product Overview

System Components and Function

Details the MagnaCleanse flushing process, its contents, and additional items required for effective system cleaning.

Step-by-Step Installation Guide

Initial System Preparation

Locate the three-port valve, prepare pipework, and identify the MagnaClean filter installation location.

Connecting Flushing Equipment

Attach MagnaCleanse hoses between the RapidFlush filter and the HTV connector, ensuring correct drain valve placement.

Preparing the RapidFlush Filter

Turn off isolation valves on the RapidFlush filter and carefully remove the lid assembly from its canisters.

Adding Cleaner and System Refill

Introduce suitable cleaner into the system via the RapidFlush filter and subsequently refill and pressurise the heating system.

System Operation and Agitation

Activate the heating system, ensure radiators are fully open, and agitate the furthest radiator using the VibraClean tool.

Continuing Radiator Cleaning

Maintain VibraClean agitation until the return hose is clear, then clean the RapidFlush filter and repeat radiator cleaning.

Preparing for Cold Flush

Isolate the boiler, connect a drain hose, and temporarily cap the expansion pipe in preparation for the cold flush.

Executing the Cold Flush

Turn off HTV isolation valve 2, open the heating circuit, and flush pipework and radiators with cold mains water.

Flushing Boiler and Filter

Turn on HTV isolation valve 2, turn off HTV isolation valve 1, and flush the boiler and RapidFlush filter with cold water.

System Refill and Inhibitor

Refill the header tank, add inhibitor, and vent any air from the filter after completing the flushing stages.

System Restart and Final Checks

Turn on the system, reset controls, open bypass valves, and prepare for the final commissioning process.

Commissioning and Servicing

Commission the system according to manufacturer guidelines and service the MagnaClean filter, verifying for leaks.